• DS4D 420kV 550kV High voltage disconnect switch
DS4D 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS4D-550/4000-63
DS4D-550/2500-50
DS4D-420/4000-63
DS4D-420/2500-50
Basic info
Brand ROCKWILL
Model NO. DS4D 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS4D
Product Detail

Product introduction

This switch Switch Disconnector is a Kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz.lt is used for breaking or connecting HV lines under no loads so that there lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and dose the bus to switch current

Main characteristic

  • The product chassis adopts an integrated design to ensure that the upper conductive does not generate a large displacement under the tensile force of the terminal, and improves the reliability of the product closing.
  • The bearing housing is designed according to the maintenance-free requirements. The bearing seat is sealed by a fully sealed rain cover, wool felt seal and sealing ring. Water vapor, dust and harmful gases cannot enter, and the grease in the bearing does not drain during the life cycle., does not cure, especially suitable for Windy sand areas
  • The finger is made of pure copper and has a silver plating process. It has strong flow capacity and tong mechanical life. The stamping process ensures the reliability of contact and finger contact
  • The contact finger pressure is proportional to the primary insertion depth of the contact, the sensitivity is low, the contact insertion area is long, the on-site debugging is difficult, and the product is highly reliable against adverse interference such as harsh environment (winding of the flexible Wire).
  • The earth switch uses a torsion spring to balance its own weight and torque, making it light and flexible. The base adopts a suspended structure. which is convenient for on-site adjustment. The grounding switch static contact adopts self-powered plum-shaped finger. which has simple structure, many contact points and high technical performance index.
  • Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

Order notice 

Please indicate the service condition;

Please indicate the product type、 Rated voltage、 Rated current、 Rated short time withstand current、creepage distance and so on;

Please indicate the motor voltage、 control circuit’s voltage、pollution region and auxiliary switch connection number;

Please indicate whether the steel bracket is provided;

Please indicate whether the interphase cable is provided, and specify the cable length and type;

Please indicate other special requirements

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!