• DS4A  12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
discuss personally
Model
DS4A-170/2000-40
DS4A-145D/4000-50
DS4A-145D/3150-50
DS4A-145D/2500-40
DS4A-145D/2000-40
DS4A-145D/1600-40
DS4A-126D/4000-50
DS4A-126D/3150-50
DS4A-126D/2500-40
DS4A-126D/2000-40
DS4A-126D/1600-40
DS4A-72.5D/4000-50
DS4A-72.5D/3150-50
DS4A-72.5D/2500-40
DS4A-72.5D/2000-40
DS4A-72.5D/1600-40
DS4A-72.5D/1250-40
DS4A-40.5D/4000-50
DS4A-40.5D/3150-40
DS4A-40.5D/2500-40
DS4A-40.5D/2000-31.5
DS4A-40.5D/1250-31.5
DS4A-24D/2000-31.5
DS4A-24D/1250-31.5
DS4A-24D/630-31.5
DS4A-12D/2000-31.5
DS4A-12D/1250-31.5
DS4A-12D/630-31.5
Basic info
Brand ROCKWILL
Model NO. DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
Rated voltage 145kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS4A
Product Detail

Product introduction:

DS4A-12/126/145/170D(W) Switch Disconnector are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It’s used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker.

This product has two insulators with horizontal center breaks. itis openable in the middle and accessible to the grounding switch on one side or two sides. The Switch Disconnector adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage. The earthing switch adopts CS14G manual operating mechanism to realize tri-pole linkage.

In August 2005, this product passed the improvement technology review by State Grid Corporation (Jiangsu provincial branch).

DS4A Switch Disconnector comprises three single poles and operating mechanism. Each pole comprises a base, post insulators and conductive parts. Removable insulating posts are mounted at both sides of a long base, The conducive switch blade's contact arms are respectively fixed at the tops of the insulating posts. When the insulating post at one end of the actuator revolves to drive, with the help of the crossover lever, the reverse rotation of the insulating post at the other end by 90", the conductive switch blade will rotate on the horizontal surface to realize the starting and closing of the isolating switch. A horizontal insulating open break will appear at the opening moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight, large radiation area and corruption-resistance.
  • Adopt particular copper alloy to develop the self-contained contact, The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat of the contact. The contact is made of curved copper plate, forming a large connection area with he conductive arm. In the opening and closing processes, there isa short trip of friction between the contact and the finger and he required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.. Z103 2 20022.6)
  • The rotating parts of the disconnect switch are designed to be free of any maintenance. The rotating base is designed into a seal structure which denies the access of moisture, dust and harmful gases so that No.2 low-temperature lubricating cream within the bearing will not run off or harden, Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

GW4A-parameters.png

Order notice :

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods ordering time;

The disconnect switch offers several options of grounding (no, left. right. both left and right). Unless otherwise specified, the goods supplied will be considered as proving the option of right grounding;

Notes:

  • The methods of Judging left and right grounding: hold out both arms and keep the arms In the same direction as the Switch Disconnector is open的The earthing switch will be considered as left grounding if on the left hand side, and right grounding if on the right hand side;
  • The actuator's model and name, voltage and the number of contacts for auxiliary switch;
  • Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!