Key attributes

Brand MV Switchgear Accessories
Model NO. Digital Timer Switch THC 15A-2C Astronomical Timer
Rated voltage AC220V
Rated normal current 20A
Rated frequency 50/60Hz
Series THC-15A-2C

Product descriptions from the supplier

Description

The THC-15A/20A/30A series timer is equipped with 16 sets of time settings, which have functions such as error correction, power-off memory, and precision sensitivity. It can ensure stable product operation, precise timing control, and achieve intelligent cycling effect. Meanwhile, the THC-15A/20A/30A series editable timer is commonly used in places such as street lamps, light boxes, neon lights, production equipment, agricultural breeding, warehouse ventilation and dehumidification, automatic preheating, broadcasting and television equipment, etc. It has a wide range of applications and strong practicality, making it a cost-effective timer.

THC15A/20A/30A series editable timer product features:
1. With precision and sensitivity, the product can operate stably.                                                                        
2. Equipped with power-off memory function.
3. It has error correction function.
4. There are 16 sets of adjustable times.
5. The product has a built-in battery that can run continuously after a power outage.
6. Installation of 35mm standard card rail.

Features

ItemNo

THC15A-2C 16A, 20A,25A,30A, THC15B-2C 16A, 20A,25A,30A

Voltage range

AC 220-240V 50Hz/60Hz(Other special voltages can be customized)

Timing error

AC 180-250V

Switching frequency

≤1s/d (25℃)

Power consumption

8ON+8OFF

Display

4VA (max)

Electrical life

LCD

Mechanical life

10⁵times (Rated load)

Min. switching time

1min

Contact

2NO+2NC/ 2NC

Control current

16A,20A,25A,30A

Mounting

DIN rail mounting

Contact Capacity

THC15A-2C 16A Resistive: 16A/250V AC(cosφ=1)  THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)
THC15A-2C 20A Resistive: 20A/250V AC(cosφ=1)     THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)
THC15A-2C 25A Resistive: 25A/250V AC(cosφ=1)     THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)
THC15A-2A 30A Resistive: 30A/250V AC(cosφ=1)     THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)

QTY

100PCS

G.W

19KG

N.W

18.5KG

MEAS

460x320x290mm

Temperature

-10~40℃

Relative humidity

35~85%RH

Documentation Resource Library
Restricted
Digital Timer Switch THC 15A-2C Astronomical Timer Catalogue
Catalogue
English
Consulting
Consulting
FAQ for
Q: What are the core functions and advantages of the THC 15A-2C?
A:

The core functions and advantages focus on three dimensions: astronomical adaptation, dual-channel control, high reliability:

· Precise astronomical timing: Automatically matches sunrise and sunset times after entering latitude and longitude, intelligently adjusts with seasonal sunlight changes, no manual modification required;

· Dual-channel synchronous/independent control: 2 groups of contacts support synchronous (control the same load) or independent (control two loads) operation, adapting to multi-device scenarios;

Highly flexible programming: 80 custom programs can be superimposed with astronomical mode (e.g., "turn on lights 10 minutes before sunset"), minimum switching time 1 minute;

· Stable and durable: Built-in lithium battery ensures power failure memory; industrial-grade chip resists electromagnetic interference; operating temperature -10~40℃, adapting to complex environments.

Q: What is the THC 15A-2C Astronomical Timer Switch?
A:

The THC 15A-2C is a latitude-longitude driven dual-channel astronomical timer switch, compatible with AC 220-240V/50-60Hz voltage, with rated currents covering 16A/20A/25A/30A (resistive load). Its core function is to automatically calculate daily sunrise and sunset times by inputting the latitude and longitude of the installation location, realizing automatic circuit on/off with natural light. It also supports 80 groups of custom on/off programs, power failure memory (built-in lithium battery life ≥3 years), industrial-grade anti-interference, and DIN rail mounting. Its size fits distribution cabinets, widely used in municipal street lights, landscape lighting, agricultural aquaculture, etc.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.