• CLMD Series Capacitors unit
CLMD Series Capacitors unit
discuss personally
Model
CLMD45-30/0.38
CLMD45-20/0.38
CLMD45-5/0.38
CLMD45-2.5/0.38
CLMD33S-16/0.23
CLMD33S-10/0.23
Basic info
Brand Wone Store
Model NO. CLMD Series Capacitors unit
Rated voltage 230V
Rated capacity 10kVA
Series CLMD Series
Product Detail

Overview

Design

The building block of each CLMD capacitor unit is a capacitor winding. These windings undergo vacuum treatment to ensure consistent electrical characteristics. Each winding is then placed in a plastic case and

encapsulated in thermo-setting resin in order to obtain a perfectly sealed element. Elements are combined together to form the capacitor unit.

Electrical characteristics

Dielectric losses are less than 0.2 Watt per kvar. Total losses, including discharge resistors, are less than 0.5 Watt per kvar.

Available for single and three-phase systems The elements are placed inside a box made of sheet steel and connected in such a way as to supply the single or three-phase power at the required voltage and frequency.

Safe performance throughout the capacitor’s life
● The dry type dielectric makes the CLMD capacitors leakage free, minimizing the impact on the environment.
● The sheet steel box is filled with vermiculite which is an inorganic, inert and fireproof material that can absorb the energy produced or extinguish any flames in case of a possible defect at the end of an element’s life.
● In the event of a fault developing in the dielectric of the capacitor, the metallized electrode adjacent to the fault is immediately vaporized, thus isolating the fault. The capacitor then continues normal operation. This is commonly called the ‘self-healing’ principle.
● The capacitor windings are provided with a sequential disconnecter ensuring that each element can be reliably and selectively disconnected from the circuit at the end of its life.
● CLMD capacitors are provided with thermal equalizers to ensure effective heat dissipation. Discharge resistors are also included.
● The use of robust terminals minimizes the risk of damage during installation and reduces maintenance requirements.
● The capacitors comply with the requirements of IEC 60831-1 & 2.

High performance in-house metallized film
Completely integrated manufacturing process has resulted in the development of a special high-performance in-house metallized film from which all CLMD capacitors bene-fit. This film gives high breakdown strength, excellent peak cur-rent handling capability, and high capacitance stability and has an optimal self-healing design and a long life.

Technology parameters

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
capacitors CLMD Data sheet
White paper English
Consulting
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!