• CKSS-12 Electrical ring main unit switchgear
CKSS-12 Electrical ring main unit switchgear
discuss personally
Model
CKSS-12
Basic info
Brand ROCKWILL
Model NO. CKSS-12 Electrical ring main unit switchgear
Rated voltage 12kV
Rated frequency 50/60Hz
Series CKSS
Product Detail
Description

As industrial enterprises and institutions build new buildings, from the perspective of power supply and distribution, distribution transformers are generally small and medium-sized, with a capacity of no more than 1250kva, long-term reliable power supply and infrequent operation of high-voltage switches. For this kind of users, the functions of ring network cabinet are not the most complete, but they can best meet the requirements of ring network. Due to large-scale urban construction, many large-scale high-rise buildings have sprung up, and substations are often located downstairs. According to the fire protection requirements, substations and distribution equipment must be "oil-free", and with regard to the rational use of building area, transformers and distribution equipment. Due to the need for further miniaturization of equipment, annular bodies, vacuum circuit breakers, dry-type transformers and dry-type transformers are suitable for high-rise buildings under construction. The ring network cabinet has the advantages of simple structure, stable and safe operation, low maintenance cost and low operation cost. Compared with the switchgear with circuit breaker, it has outstanding advantages. The ring main cabinet needs higher function and smaller size load switch.

Product features

Cabinet structure: the inflatable compartment is made of 3 ~ 5mm thick stainless steel plate, which is welded by welding robot after being processed by NC machine tool, with less welding deformation and good air tightness. The other compartments are made of high-quality cold-rolled steel plate, which is welded after NC bending, with the characteristics of high precision and good strength; Each functional unit is an independent module, which is very convenient for assembly. Each sealed compartment of the cabinet is equipped with an independent pressure relief channel to ensure personal safety and equipment operation to the greatest extent. b. Protection grade: IP67 for inflation isolation; Low voltage cabinet is IP4X.

Normal service conditions

  • Ambient air temperature: maximum 40 ℃, (average value within 24 hours shall not exceed 35 ℃), minimum - 25 ℃

  • Altitude: no more than 3000m (coordinate with the manufacturer when it exceeds 3000m)

  • Air humidity: the average value of daily relative humidity shall not be greater than 95%, and the average value of monthly relative humidity shall not be greater than 90%

  • The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kV

Technical parameter

Rated voltage

kV

12

Power frequency withstand voltage

phase to phase/earth

kV

42

Power frequency withstand voltage

Between open contacts

kV

48

Impulse withstand voltage phase to phase/earth

kV

75

Impulse withstand voltage

Between open contacts

kV

85

Rated frequency

Hz

50

Rated current

A

630

Rated short-time withstand current (4s)

kA

20/25

Rated peak withstand current

kA

50/63

Rated active load breaking current

A

630

Rated closed loop breaking current

A

630

Mechanical lifetime

Ops

10000

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!