• SF6-free air-insulated switchgear for secondary distribution/Ring Main Unit
SF6-free air-insulated switchgear for secondary distribution/Ring Main Unit
discuss personally
Model
UniSec Air-24
Basic info
Brand ABB
Model NO. SF6-free air-insulated switchgear for secondary distribution
Rated voltage 24kV
Rated frequency 50/60Hz
Series UniSec Air
Product Detail

Description:

UniSec Air is a medium voltage switchgear designed for secondary distribution up to 24kV, 630A, 20kA. It contains GSec Air, three-position load break switch or disconnector and earthing switch. This new component has a shunt vacuum interrupter for breaking capacity, dry air as the insulation medium, and a global warming potential (GWP) of zero. The switchgear also contains a vacuum circuit breaker and is fully compliant with IEC standards and the U F-gas regulation (EU) 2024 / 573. 
The switchgear is based on a highly flexible and modular  concept with standardized solutions that can be  readily configured to meet the specific needs of each application. UniSec Air is fully tested according to IEC standard 62271-200. 
UniSec Air is internal arc classified, IAC A FLR up to 20 kA, assuring safe operations for technicians when standing in  front of the switchgear. Robust control and protection, metering, monitoring, and diagnostics suitable for various applications are also available. 
UniSec Air is designed with a refined interface and with  the same footprint, operations, and backward compatibility as the original UniSec switchgear,facilitating integration into existing systems and extensions of the installed base.

Customer benefits:

F-gas regulation compliance 

  • Fully compliant with the EU F-gas regulation (EU) 2024 / 573

  • GWP of 0

Flexible and modular design

  • Better accessibility to MV cable connection and simplified installation, use, and maintenance.

  • Wide range of functional units equipped with LBS and disconnector, circuit breaker, conventional measuring transformers, current and voltage sensors, and protection relay solutions, making it suitable for most indoor applications.

  • Provides flexibility for a high level of customization to meet demanding requirements and is easy to order thanks to user-friendly configurator tools.

  • Compact design with multiple functional units width 375, 500 and 750mm for installation in a wide variety of electrial rooms and layouts.

  • Backward compatibility between UniSec Air and UniSec allows for easy integration into existing systems and extensions of the installed base.

 Safe and Reliable

  •  Internal arc classification available with various gas exhaust variants  for enhanced safety.

  • Service continuity solutions LSC2B / LSC2A / LSC2 tailored for application needs, ensuring minimal service interruption.

  • High operator safety features an internal arc-proof design and a wide range of mechanical and electrical interlocks to enhance operator safety.

  • The GSec Air component has an internal volume of less than 25 liters.

  • Fast and dependable delivery times with pre-engineered just to install (JTI) switchgear solutions.

Main Technical Characteristics:

 GSec Air:

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
SF6-free air-insulated switchgear for secondary distribution
Manual English
PDF
FAQ
Q: What standards and certifications that ABB’s medium voltage switchgear products comply with?
A:
Our medium voltage switchgear products comply with international standards such as IEC 62271, GOST, GB/DL. They are also certified by leading industry bodies to ensure the highest levels of safety and performance. ABB also offers medium voltage switchgear products for ANSI standards.
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A:
Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!