38.5kV 44kV 45kV 46kV Maintenance-Free Environmental Protection no gas switchboard panel Original Manufacturer

  • 38.5kV 44kV 45kV 46kV Maintenance-Free Environmental Protection no gas switchboard panel Original Manufacturer

Key attributes

Brand ROCKWILL
Model NO. 38.5kV 44kV 45kV 46kV Maintenance-Free Environmental Protection no gas switchboard panel Original Manufacturer
Rated voltage 12kV
Rated frequency 50/60Hz
Series EcoRing

Product descriptions from the supplier

Description

Description

The 38.5kV 44kV 45kV 46kV Maintenance-Free Environmental Protection Gas Ring Network Cabinet is a high-performance medium-voltage power distribution device designed for modern smart grids. It integrates eco-friendly insulating gas technology with maintenance-free design, effectively replacing traditional gas-insulated equipment that relies on high-GWP (Global Warming Potential) gases. As a core component in power distribution systems, it is widely used in urban distribution networks, industrial parks, and commercial complexes—providing stable, safe, and low-carbon power support for end users. By optimizing the gas chamber structure and adopting high-quality sealing materials, it eliminates the need for regular gas replenishment and component inspection, while the environmentally friendly gas meets international low-carbon standards, aligning with global energy conservation and emission reduction goals.

Feature

  • Dual Advantages of Environmental Protection & Maintenance-Free:Adopts low-GWP environmental protection gas (compliant with eco-friendly standards) to avoid environmental pollution; the hermetic gas chamber and wear-resistant components realize long-term maintenance-free operation, reducing operation and maintenance costs.

  • High Operational Safety & Stability:Equipped with advanced gas insulation technology, it has strong resistance to humidity, dust, and corrosion; the built-in overvoltage and short-circuit protection functions ensure stable power supply even in harsh working environments.

  • Compact Design for Flexible Installation:The compact structure saves installation space, making it suitable for narrow areas such as urban underground power stations and industrial workshops; it supports modular combination to meet diverse distribution network layout needs.

  • Smart Monitoring for Predictive Management:Optional intelligent online monitoring system tracks gas pressure, temperature, and operating status in real time; it sends early warnings for abnormal conditions, helping users achieve predictive maintenance and improve grid management efficiency.

Product Parameters

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

General

Unit

Parameter

Rated Voltage

kV

12

Rated Frequency

Hz

50

Power Frequency Withstand Voltage

V/min

42/28

Lightning Impulse Voltage

kV

75/85

Arc Duration

s

1

Primary Component Protection Level (excluding metering cabinet)

IP67

Cabinet Protection Level

IP4X

Isolation Room Protection Level

IP2X

Operating Power Supply Voltage

V

DC: 24 48 110 220

AC: 110 220

Application Field:

Urban and rural distribution network renovation projects   

Supporting systems for new energy power stations  

Power distribution systems in industrial plants  

Commercial complexes and high-rise buildings  

Power supply systems for rail transit

FAQ for
Q: Is dry air a common insulation medium for 12kV environmentally friendly cabinets?
A:
Yes, dry air is one of the most common insulation media for 12kV environmentally friendly cabinets. It is non-toxic, non-greenhouse effect, low-cost, and easy to prepare. The key requirement for dry air in 12kV cabinets is a dew point of ≤ -40℃ (even ≤ -50℃ in high-demand scenarios) to ensure insulation performance. Many mainstream manufacturers (e.g., Guangyun Electric, Kangjin Electric) use dry air in their 12kV eco-friendly RMU products.
Q: What is the difference between N2 and N2/CO2 mixture used in environmentally friendly cabinets?
A:
Nitrogen (N2) has stable chemical properties, no greenhouse effect, and good low-temperature resistance (no liquefaction in alpine regions), but its insulation performance is moderate. The N2/CO2 mixture adjusts insulation and heat dissipation performance by optimizing the mixing ratio. However, CO2 is a greenhouse gas, which limits its application in highly eco-friendly scenarios. N2 is more suitable for single-insulation scenarios, while N2/CO2 mixtures are used in scenarios requiring balanced insulation and heat dissipation.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.