• 35kV Solid Insulated Ring Main Unit/switchgear
35kV Solid Insulated Ring Main Unit/switchgear
discuss personally
Model
GMSS-35/630
Basic info
Brand ROCKWILL
Model NO. 35kV Solid Insulated Ring Main Unit/switchgear
Rated voltage 35kV
Rated frequency 50/60Hz
Series GMSS
Product Detail
Description

Fengyuan developed this solid insulated ring main unit product according to market demand. This unit has the following advantages: modularity, high electrical performance, high environmental protection and easy installation. Equipped with intelligent controllers such as FTU and other related equipment, the ring host can achieve different levels of control, measurement and protection functions to meet the various needs of customers.

Feature

  • Enhanced solid insulation performance for 35kV: Utilizes high-strength solid insulating materials such as epoxy resin, with insulation structure specially optimized for the 35kV voltage level. It features high and stable insulation strength, unaffected by environmental factors like humidity, dust, and contamination. It can effectively withstand electrical stress under high voltage, significantly reducing the risks of flashover and breakdown, and ensuring the long-term reliable operation of medium and high-voltage power distribution systems.
  • Fully eco-friendly gas-free design: Abandons greenhouse gases such as SF₆, fundamentally eliminating environmental hazards caused by gas leakage and subsequent links like gas monitoring and 补气 (gas replenishment) in operation and maintenance. It complies with international environmental standards and the development trend of green power grids, and is particularly suitable for 35kV power distribution scenarios with strict environmental requirements, such as ecological protection zones and urban core areas.
  • Compact high-voltage adaptive structure: Combines a metal-enclosed shell with a modular layout, significantly reducing equipment volume while meeting the 35kV high-voltage insulation distance requirements. Its floor area is only 50%-70% of traditional open-type equipment, facilitating installation in space-constrained high-voltage power distribution sites such as substations and large industrial plants, and simplifying site planning and layout.
  • Multiple high-voltage safety protection mechanisms: Equipped with 35kV-specific mechanical and electrical interlocking devices to strictly prevent dangerous operations such as on-load switching, incorrect grounding, and entry into live compartments; the fully enclosed metal shell effectively shields high-voltage electric fields, with built-in high-voltage live display and grounding status monitoring functions, comprehensively ensuring the safety of operation and maintenance personnel and equipment in high-voltage environments.
  • Long-life and low-maintenance characteristics: Solid insulating materials have excellent anti-aging and corrosion-resistant properties; core high-voltage components are completely isolated from the outside, reducing component losses caused by high-voltage arcs and environmental erosion. It can achieve maintenance-free operation for more than 20 years, significantly lowering the life-cycle maintenance costs and shutdown risks of 35kV equipment.
  • Flexible high-voltage distribution compatibility: Supports multiple 35kV wiring methods such as ring network power supply, dual power supply switching, and radial distribution. It can be seamlessly connected with transformers, cable branch boxes, GIS equipment, etc., of the same voltage level, adapting to diverse 35kV power distribution needs in urban medium and high-voltage distribution networks, large industrial enterprises, new energy power stations (wind power, photovoltaic), etc.

Application

The solid insulated ring main unit adopts a rotary fuse structure inside, which makes it very easy to replace the fuse cabinet type. The size of the device is the smallest among all gas-insulated cabinets, the floor space is the smallest, and it is environmentally friendly for the power supply and distribution of urban users and residential applications.

Working environment

  • Maximum temperature: +50℃; lowest temperature: -40℃
  • Humidity: daily average does not exceed 95%, monthly average does not exceed 90%
  • Earthquake intensity: Grade 8
  • Altitude: ≤5000 meters
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!