• AC load bank 3KW-5MW
AC load bank 3KW-5MW
discuss personally
Model
DRLB-200
DRLB-150
DRLB-120
DRLB-100
DRLB-20
DRLB-10
DRLB-5
DRLB-3
Basic info
Brand Wone
Model NO. AC load bank 3KW-5MW
Power 100KW
Series DRLB
Product Detail

Description

  • It is used for the detection and maintenance of AC power supply equipment, performance testing of various switches and contactors, loading,
    burn-in, simulated load test, etc.

  • Power Range: 1kW-5MW (others on request).

  • Current Range: 0.1A-15000A.

  • Working Voltage Range: single phase, 3 phases, or custom requests.

  • Multiple safety protection functions : short circuit, over-current, over voltage, over-load, over temperature, fan fault, audible and visual alarm
     device, etc.

  • It can be designed with RS232 and RS485 to connect with PC for remotecontrol.

  • Forced air cooling and water cooled are available.

  • Production Time :3-4 weeks
    Widely used in test equipment, such as generator load, charging pile test,inverter power supply, data center test, server room load test, UPS, etc.


Parameter

Dimensions (mm)
Power L±5 W±5 H±5 h±5
3KW 580 380
250
70
5KW 680 380 250 70
6KW 680 450 250 70
8KW 450
500 700
70
10KW 500 500 800 100
15KW 500 550 800 100
20KW 600
600 800 100
25KW 600 650 800 100
30KW 600 650 1000
100
40KW 680
680
1100 100
50KW 680 680 1200 100
60KW 850
850
1200 100
80KW 850 850 1300
150
100KW 850
850 1400 150
120KW 900 850 1400 150
150KW 900 850 1500
150
200KW 1000
850 1500 150
300KW 1400 1200 1650 150
400KW 1500 1200 1800
150
500KW 1500
1400 1800 150
600KW 1500 1500 1800 150
800KW 1800 1500 1900
150
1000KW 2000
1500 1900 150
1200KW 2000 1600
1900 150
1500KW 2200 1600 1900 150
2000KW 2400 1800
2000
150



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!