66MVA/22kV Station Transformer(Transformer for generation)

  • 66MVA/22kV Station Transformer(Transformer for generation)

Key attributes

Brand ROCKWILL
Model NO. 66MVA/22kV Station Transformer(Transformer for generation)
Rated frequency 50/60Hz
Series S

Product descriptions from the supplier

Description

Description of Station Transformer

The Station Transformer (referred to as "station transformer" for short) is a specialized transformer responsible for providing on-site power supply in power hubs such as substations and power plants. Its core function is to step down the high-voltage electricity from the power grid (e.g., 110kV, 220kV, 500kV) to low voltage (380V/220V) to supply power to auxiliary facilities in the station, including control circuits, lighting systems, cooling equipment, communication devices, and pump machinery. As the "internal energy hub" of power facilities, it does not directly participate in external power transmission but maintains the stable operation of core links such as monitoring, protection, and operation and maintenance of the entire power station. It is a key device ensuring the safe and reliable operation of power hubs.

  • 3-Ph 66MVA/22kV, Dyn1-yn1, ONAN/ONAF

  • Supply station transformer for all the type of power plant, the range covers from S-50kVA/6kV to SFFZ-40000kVA/66kV.

Features of Station Transformer

  • High-reliability design: Adopts redundant configuration (e.g., "one main and one standby") and supports seamless switching to avoid power loss in the station due to a single unit failure. Core components are made of anti-aging materials to ensure long-term continuous operation (annual operating time usually exceeds 8000 hours).

  • Flexible adaptability: The primary side voltage matches the high-voltage level of the local power grid (10kV–500kV), and the secondary side outputs standard low voltage of 380V/220V. The winding structure can be adjusted according to the type of on-site load (inductive, capacitive) to meet the power demand of power equipment such as water pumps and fans, as well as precision control instruments.

  • Miniaturization and integration: The capacity is usually 50kVA–40000kVA (much smaller than the main transformer), with a compact structure. It can be installed in indoor switch cabinets or outdoor box-type enclosures to save space in the station. Some dry-type station transformers use epoxy resin casting, without oil conservators, adapting to narrow environments.

  • Comprehensive protection mechanism: Equipped with built-in overcurrent, overvoltage, zero-sequence protection, and temperature monitoring devices. Oil-immersed station transformers are fitted with gas relays, and dry-type station transformers have high-temperature alarm functions, which can quickly respond to faults such as short circuits and overloads to protect themselves and downstream loads.

  • Dual focus on energy efficiency and environmental protection: Complies with the latest energy efficiency standards (e.g., GB 20052). Uses low-loss silicon steel sheets and optimized winding design, reducing no-load loss by more than 15% compared with traditional models. The oil-free design of dry-type station transformers avoids oil leakage pollution, making them suitable for power stations in ecologically sensitive areas.

FAQ
Q: What are the core differences in application scenarios between oil-immersed and dry-type power transformers up to 345kV?
A:
The application differences between the two are mainly determined by their insulation characteristics and voltage adaptability, with specific distinctions as follows:
  • Oil-immersed transformers: Offer superior insulation and cooling performance, making them the preferred choice for power transmission applications. They can stably adapt to voltage levels up to 345kV and above, covering a capacity range from a few MVA to hundreds of MVA. Their cooling methods comply with international standards, enabling them to meet the requirements of complex outdoor and high-voltage transmission scenarios.
  • Dry-type transformers: Due to their insulation structure, they are more suitable for indoor or specific industrial environments with special safety requirements, typically for lower voltages (up to 35kV). Only some specially designed products can be used for higher voltages. Their capacity is relatively more limited compared to oil-immersed transformers, with core advantages in strong environmental adaptability.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.