| Brand | ROCKWILL |
| Model NO. | 6.9kV 7.2kV 12kV 24kV Solid Insulated Metal-enclosed ring main unit/distribution board |
| Rated voltage | 12kV |
| Rated frequency | 50/60Hz |
| Series | CKSS |
Pioneer in China's eco-friendly switchgear sector, we have specialized in R&D and manufacturing of SF₆-free switchgear for decades. With core technologies, we have established industry standards. Boasting a fully independent end-to-end production chain, we have built a product matrix of zero-emission and high-reliability eco-friendly switchgear, making us a trusted choice for power grid construction.
The ring main unit is insulated metal common tank enclosed switchgear, consisting of load break switch unit, load break switch fuse combination electrical unit, vacuum circuit breaker unit, and the incoming line unit of bus. It adopts a range of advanced technologies and materials, with excellent electrical and mechanical properties, less affected by environment and climate, in small size, easy to install, easy to operate, with no need of maintenance, and can be flexibly combined. Its clear and intuitive design ensures simple and direct operation, the feeder's connection capacity is large, suitable for a variety of wiring systems.
Feature
Unit code |
Meaning |
C |
Standard single casing load break switch unit |
F |
Load break switch and fuse combination |
V |
Apparatus unit |
D |
Cable unit(without switch) |
+ |
Side casing of busbar |
- |
Top casing of busbar |
SL |
Bus couple unit |
M |
Metering unit |
PT |
PT unit |
1K2(4) |
Double-sleeve outgoing load break switch unit |
Technical Sheet
The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.
ltem |
Unit |
Load break switch unit |
Combination apparatus |
Fuse unit |
|
Rated voltage |
kV |
12/24 |
12/24 |
12/24 |
|
Rated frequency |
Hz |
50 |
50 |
50 |
|
Rated current |
A |
630 |
Depend on rated current of fuse |
630 |
|
P.F.withstand voltage (phase to phase.phase to earth) |
kV |
42/65 |
42/65 |
42/65 |
|
Ated insulation levels |
P.F.withstand voltage(Across open contacts) |
48/79 |
48/79 |
48/79 |
|
P.F.withstand voltage (Control and auxiliary circuit) |
2/2 |
2/2 |
2/2 |
||
Lightning impulse withstand voltage (phase to phase, phase to earth) |
75/125 |
75/125 |
75/125 |
||
Across open contacts |
85/145 |
85/145 |
85/145 |
||
Ogauge pressure test |
- |
Pass |
Pass |
Pass |
|
Rated short time withstand current |
kA |
20/4s/20/3s |
- |
20/4s/20/4s |
|
Rated peak withstand current |
kA |
63 |
- |
63 |
|
Rated short circuit making current |
kA |
50 or 63 |
Subject to high-voltage fuse |
50 |
|
Rated short circuit breaking current |
kA |
- |
Subject to high-voltage fuse |
20/20 |
|
Rated transform current |
A |
- |
1750/1400 |
- |
|
Rated active load breaking current |
A |
630 |
- |
- |
|
Rated Closed loop breaking current |
A |
630 |
- |
630 |
|
Mechanical life |
Load break switch/breaker |
Time |
5000 |
5000 |
10000 |
Isolating switch/earthing switch |
5000 |
5000 |
5000 |
||
Loop resistance |
μΩ |
≤120 |
- |
≤120 |
|
Inflation pressure |
Rated inflation pressure(absolute pressure) |
bar |
1.3 |
1.3 |
1.3 |
Minimum inflation pressure(absolute pressure) |
1.2 |
1.2 |
1.2 |
||
Relative rate leakage of gas |
% |
≤0.02 |
≤0.02 |
≤0.02 |
|
Remark: l :Neutral point earthing system through low resistance