• 6.6kV Three-phase Power Distribution Transformer
6.6kV Three-phase Power Distribution Transformer
discuss personally
Model
S11-1500/6.6
Basic info
Brand Vziman
Model NO. 6.6kV Three-phase Power Distribution Transformer
Rated capacity 1500kVA
Voltage grade 6.6KV
Series Distribution Transformer
Product Detail

Product overview:

  • High reliability of operation verification in more than 50 countries and regions around the world.

  • Mainly used in power generation enterprises, industrial and mining enterprises, water conservancy facilities, petrochemical enterprises 6.6 kV power distribution system.

  • Products are mainly exported to southeast Asia, East Asia, Central Asia and other developing countries and regions.

  • Standards: IEC 60076 series, IEC 6013, IEC 60214-1, IEC 60296; GB1094 series, GB/T6451-2015, GB/T7597-2007, etc.

Product advantages

Leading technology:

  • High pressure copper tape winding technology, improve lightning resistance.

  • Low voltage copper foil winding technology, high quality A class insulation material insulation.

  • Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure.

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baosteel, Wisco, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

 High quality material:

  •  Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25# 40#).

 Other instructions:

  • The low-voltage outgoing terminal is tinned copper bar.

  • The high-voltage outlet terminals are ring tinned bolts.

  • Default no-load voltage regulation (on-load voltage regulation can be customized) Tap switch 5 or 7 speed adjustment.

  • Transformers above 630KVA are protected by gas relays.

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters.

  • Transformer operating environment (altitude, temperature, humidity, location, etc.

  • Other customization requirements (tap switch, color, oil pillow, etc.

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

    Normal delivery period of 30 days, worldwide fast delivery.

How to choose the parameters of three-phase distribution transformer?

Main Parameters of a Transformer

Rated Capacity:

  • Definition: The rated capacity of a transformer is the apparent power it can output under rated operating conditions. The unit is kilovolt-amperes (kVA) or megavolt-amperes (MVA).

  • Common Values: For a common 6.6 kV three-phase distribution transformer, the rated capacities include 100 kVA, 200 kVA, 315 kVA, 400 kVA, 500 kVA, 630 kVA, etc.

Rated Voltage:

  • Definition: Rated voltage includes the rated voltage on the high-voltage side and the rated voltage on the low-voltage side.

  • Example: For a 6.6 kV transformer, 6.6 kV is the rated voltage on the high-voltage side. The rated voltage on the low-voltage side is typically 0.4 kV or 0.69 kV, depending on the user's requirements.

Short-Circuit Impedance:

  • Definition: Short-circuit impedance is an important parameter of a transformer, indicating the impedance of the transformer under short-circuit conditions. The size of the short-circuit impedance affects the short-circuit current and the voltage drop during a short circuit, which is significant for the protection and operational stability of the transformer.

No-Load Loss:

  • Definition: No-load loss is the power consumed by the transformer when it is in a no-load state (i.e., the secondary side is open). It primarily includes hysteresis losses and eddy current losses in the core, as well as resistance losses in the windings. The smaller the no-load loss, the higher the efficiency of the transformer.

Load Loss:

  • Definition: Load loss is the power consumed by the transformer when it is in a loaded state (i.e., the secondary side is connected to a load). It primarily includes resistance losses in the windings and additional losses due to leakage flux. Load loss is proportional to the square of the load current and is an important indicator of transformer performance.

  • This translation provides a clear and concise explanation of the main parameters of a transformer, including rated capacity, rated voltage, short-circuit impedance, no-load loss, and load loss.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!