• 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
  • 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
discuss personally
Model
33kV Three Phases Tran
24kV Three Phases Tran
12kV Three Phases Tran
Basic info
Brand Rockwell
Model NO. 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
Rated voltage 33kV
Rated frequency 50/60Hz
Series H59
Product Detail

Description

With the development of the power industry, driven by urbanization,equipment intensification, technological advancements, and the urgent need for scenario adaptability, Rockwill has successfully developed the Top Mounted High/ Low Voltage Bushing Transformer (commonly known as the H59 earthing/Grounding Distribution Transformer), leveraging years of electrical design experience and integrating global advanced technical concepts.The H59 refers to a power transformer where both the high-voltage and low-voltage bushings are vertically installed on the top of the unit. This structural design allows all high- and low-voltage leads to be routed through the top, making it suitable for scenarios with strict lateral space constraints or requiring vertical busbar connections. It is a common type of oil-immersed transformer.

Service Environment

Temperature:

  • Maximum ambient temperature: +50℃;

  • Top oil temperature rise: +50℃

  • Average winding temperature rise: +55℃

Humidity: Daily average humidity 100%.

Above sea level: Maximum installation altitude: 1000m

Features

  • Reliable Grounding Protection: Specifically designed for grid grounding, it effectively suppresses fault currents to ensure system stability and personnel safety.

  • Outdoor Environment Adaptability: With a sealed pad-mounted structure, it is waterproof, dustproof, and corrosion-resistant, suitable for complex outdoor conditions like humidity and dust.

  • Space-Optimized Design: Pad-mounted installation saves ground space, ideal for land-intensive scenarios such as urban power distribution networks and commercial parks.

  • Three-Phase Balanced Power Supply: Supports three-phase four-wire systems, balancing power and lighting loads with high efficiency and minimal voltage fluctuation.

  • Convenient Maintenance: Centralized top bushing layout eliminates the need for complex opening during 检修 (maintenance), reducing downtime and costs.

  • High Compatibility: Adapts to HV/LV distribution networks, directly connecting to municipal or industrial power systems, and flexibly integrating with grounding compensation equipment.

Main Technical Parameters

Outline Drawing Reference

Reference Photos

Know your supplier
Rockwell
Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
60000m²
占位
占位
Documents
Public.
15kV 20kV 30kV Three Phases Transformer Pad Mounted HV/LV earthing/Grounding distribution transforme
Manual English
PDF
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!