• 33-38kV Dry-type Distribution Transformer 800kVA/1000kVA/1250kVA/1500kVA
33-38kV Dry-type Distribution Transformer 800kVA/1000kVA/1250kVA/1500kVA
discuss personally
Model
SC (B) 10-33kV-1500KVA
SC (B) 10-33KV-1250KVA
SC (B) 10-33kV-1000KVA
SC (B) 10-33KV-800KVA
Basic info
Brand Vziman
Model NO. 33-38kV Dry-type Distribution Transformer 800KVA/1000KVA/1250KVA/1500KVA
Rated voltage 33-38kV
Rated capacity 1500kVA
Series SC (B) 10
Product Detail

Descripton:

SC (B) 10 epoxy resin cast dry-type transformer is manufactured according to standard of Dry-type Power Transformer, characterized with low performance loss, good energy saving effect, economic operation and no maintenance. In addition to high process structure metal, short-circuit resistance and lightning impulse level, it is still characterized with flame retardant, damp-proof, dust-proof and low noise, which can be connected to load center. It is widely used in high-rise buildings, airport, station, wharf, power plant, transformer substation, etc., especially applicable to be used in places with high fire protection requirements for flammable and combustible materials.

Parameter:

  •  See the table for main performance parameters of SC (B) 10.

  •  Number of phases: 3-phase.

  •  Frequency: 50Hz.

  •  Insulation endurance class: Class F.

  • Average temperature rise of winding: ≤100K.

  •  Magnitude of partial discharge: <5pc.


image.png

Insulation level:

image.png



 How to maintain and maintain dry-type distribution transformers?

Maintenance and Care:

  • Regular Inspection: Regularly inspect the operating status of the transformer, including its temperature, sound, and appearance.

  • Cleaning: Keep the surrounding environment of the transformer clean to prevent dust and debris from entering the interior of the transformer.

  • Ventilation: Ensure sufficient ventilation for the transformer to avoid overheating.

  • Load Monitoring: Monitor the load condition of the transformer to avoid running it under overload for a long period.

  • Insulation Testing: Regularly test the insulation performance of the transformer to ensure safe operation.



Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s