• 25kV SF6 Ring Main Unit Switchgear
25kV SF6 Ring Main Unit Switchgear
discuss personally
Model
RMU-24/630
Basic info
Brand ROCKWILL
Model NO. 25kV SF6 Ring Main Unit Switchgear
Rated voltage 24kV
Rated frequency 50/60Hz
Series RMU
Product Detail
Description

The SF6 insulated switchgear is suitable for middle voltage power distribution system with a rated voltage of 11kV and 40.5kV. It could be used as RMUs in a power supply network, fault isolating switches and sectionalizing switches. If equipped with distribution automation devices (FTU/DTU) and communication devices, the SF6 insulated switchgear could communicate with the control center, measure the cable voltage, current, etc, and monitor the working status of

 SF6 gas insulated ring main unit(RMU/C-GIS)

Safe ring/plus RMR type SF6 gas insulated ring main unit is integrating with SF6 infill cabinet which gather with LBS, VCB, Fuse, ES, DS, etc.

By the perfect integration of stationary type and flexible expansion, RMR type SF6 gas-insulating compact close metal switchgear(Ring main unit) with the adoption of the modular design, is suitable for end-user or network node, meanwhile meets the requirement of all kinds of switching substations cabinet-type transformer substations and cable branch cabinets. It characters on its compact structure, safety and reliability, longevity and maintenance free.

This product is in conformity with the standards of IEC60420,

Technical data

Item

Unit

Switch

Rated voltage                                  

kV

24

Power frequency withstand voltage

kV

50

Impulse withstand voltage   

kV

125

Rated current     

A

630

active load                     

A

630

closed loop                           

A

670

off load cable charging                

A

141

earth fault                               

A

160

earth fault cable charging     

A

91

Making capacity    

kA

40

Short time current 3 sec

kA

16

Environmental Conditions

  • Suitable Altitude: ≤2000mSuitable

  • Temperature: -40℃ ~ +55℃Relative

  • Humidity: Daily mean ≤95%, monthly mean ≤90%

  • Gradation of Earthquake Damage: ≤ Level 8

Product feature

 Panel structure: The panel body is enclosed by 2mm aluminium-zinc plated steel plate after multi-bending. It is simple, firm, delicate and peculiar.

  • Busbar compartment: The busbar compartment is located in the top and connect with neighhboring panel.

  • Load break switch is a separated unit with SF6 gas.

  • Cable compartment: Approximate 75% room of connecting cable and installing fuse, earthing switch and PT.

  • Mechanism chamber and interlock: The chamber consists of operating mechanism, mechanism interlock, position indicator, auxiliary contact trip coil, charge indicator and interlock.

  • LV chamber: It is lockted in the top. It mainly used for installing instrument, relay and motor.

  • Circuit breaker compartment: The circuit breaker (SF6 or Vacuum) is located below load break switch.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!