• 252kV outdoor self-energy power high voltage SF6 circuit breaker
252kV outdoor self-energy power high voltage SF6 circuit breaker
discuss personally
Model
LW58-252(W)/T5000-63
LW58-252(W)/T4000-50
Basic info
Brand ROCKWILL
Model NO. 252kV outdoor self-energy power high voltage SF6 circuit breaker
Rated voltage 252kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series LW58-252
Product Detail

Product introduction:

The LW58-252(W) outdoor self-energy high-voltage SF₆ circuit breaker is designed for 252kV, 50Hz AC power systems, serving as a critical control and protection device for power grid interconnections. Utilizing SF₆ gas for arc quenching and insulation, it features a self-energy power arc extinguishing double-action interrupter structure paired with a new-type spring operating mechanism. Renowned for its robust switching capability, low operating power, low noise, and high reliability, its technical indicators align with advanced domestic and international counterparts.

This three-phase SF₆ circuit breaker upgrades from single-pole, single-mechanism operation to a three-phase mechanical linkage system driven by a single mechanism. This design reduces mechanical complexity, enhances three-phase linkage reliability, and eliminates the risk of single-phase misoperation.

Main characteristic:

  • Self-Energy Arc Extinguishing Technology: The double-action structure ensures stable breaking capacity under diverse loads.

  • High Operational Efficiency: Requires minimal operating power, with a mechanical life cycle of up to 10,000 cycles for prolonged reliability.

  • Superior Contact Design: Copper-tungsten arc contacts use integral sintering, withstanding high temperatures, minimal arc erosion, and over 20 full breaking operations.

Reliable Sealing & Insulation:

  • Annual SF₆ gas leakage rate < 0.5% via precision sealing technology.

  • Stringent dehumidification processes ensure SF₆ moisture content far below industry standards.

  • High insulation level with creepage distance > 31mm/kV.

Advanced Materials:

  • Arc extinguishing chamber valve plates use lightweight zinc-base alloy for stable gas dynamics and breaking performance.

  • Imported PTFE-composite nozzles offer excellent ablation resistance and consistent arc quenching.

  • Premium Components: Secondary circuit electrical units and SF₆ density relays are high-quality impact-resistant or joint-venture products.

  • Pure Spring Operating Mechanism: Forged from high-strength alloy steel, key components resist wear, ensuring low failure rates during frequent operations.

Main technical parameters:

1732504456227.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker;

  • Rated electrical parameters (voltage, current, breaking current, etc);

  • Working conditions for using (environment temperature, altitude, and environment pollution level);

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil);

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

  • The wire connecting direction of the primary upper terminal.

What are the main types of tank circuit breakers?

SF6 Gas-Insulated Circuit Breaker:

  • SF6 Gas-Insulated Circuit Breaker: Uses sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium. SF6 gas has excellent insulating properties and arc-quenching capabilities, allowing it to meet the high voltage and high current breaking and insulation requirements in a small space. It is widely used in high-voltage and ultra-high-voltage power systems.

Oil-Immersed Circuit Breaker:

  • Oil-Immersed Circuit Breaker: Uses insulating oil as the insulating and arc-quenching medium. Insulating oil has good insulating properties and heat dissipation capabilities, effectively extinguishing arcs and cooling the contacts. However, due to the fire risk and environmental pollution associated with insulating oil, its application range has gradually decreased. Currently, it is mainly used in specific situations where fire prevention requirements are not stringent.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!