• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


1~10kV Overhead Insulated Cable

  • 1~10kV Overhead Insulated Cable

Key attributes

Brand Wone Store
Model NO. 1~10kV Overhead Insulated Cable
Rated voltage 10kV
number of core 1-core
Nominal cross-sectional area 150mm²
Series JKY/JKV

Product descriptions from the supplier

Description

 

Description

The so-called overhead line is a relative cable, which is a line that transmits electric energy by the tower to erect the conductor at a certain height. For the high-voltage transmission and distribution network overhead line insulation is generally air, the previous distribution line (10kV below 380V) generally also uses bare wire, but due to the complex urban distribution environment.

Standard

This product is produced according to the standard of GB/T12527-2008 "Overhead Insulated Cable with Rated Voltage of 1kV and Below".

Scope of application

It is applicable to overhead power lines with rated voltage of 10KV and below.

Features

  • The rated voltage is 0.6/1KV, 10KV.

  •  The cable laying temperature should not be lower than 0°C.

  •  The maximum temperature of the cable in the event of a short circuit (the longest duration is not more than 5s): 160 °C for polyethylene insulation, 250 °C for cross-linked polyethylene insulation .

  •  The long-term allowable working temperature of the cable conductor: polyvinyl chloride insulation should not exceed 70 °C, and cross-linked polyethylene insulation should not exceed 90 °C.

  •  Allowable bending radius of the cable: The allowable bending radius of the cable should not be less than the diameter of the cylinder used in the cable bending test.

Product Model

  •  0.6/1KV series: JKV, JKLV, JKY, JKLY, JKYJ, JKLYJ, 16~240mm2.

  •  10KV series: JKYJ, JKLYJ, JKY, JKLY, JKLYJ/B, JKLYJ/Q, JKLYJ/Q, 10~300mm2.

Structure Size and technical parameter

 

参数.png

参数.png

 

Q: What kind of cable is the JKY/JKLY cable? 

A: JKY/JKLY cable cable is copper core (aluminum core) polyethylene insulated overhead cable. 

Q: What are the characteristics of JKY/JKLY? 

A: Its copper core (aluminum core) has good electrical conductivity and can efficiently transmit current. The polyethylene insulation layer has good insulation performance and can effectively prevent the occurrence of leakage. JKY cable structure is relatively simple, light weight, easy to install and erect, suitable for use in overhead lines. At the same time, it has a certain ability to adapt to the environment, and can work stably under normal climate and environmental conditions. 

Q: What scenarios are JKY cables mainly used in? 

A: JKY cable is mainly used in overhead power transmission scenarios, such as in rural power grid construction, because of its relatively low cost and can meet the basic power transmission needs, it is widely used in power transmission lines from substations to villages. It is also often used in small industrial parks or power distribution lines around towns.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.