12/24kV SF6 GIS for Secondary Distribution/Ring Main Unit

  • 12/24kV SF6 GIS for Secondary Distribution/Ring Main Unit

Key attributes

Brand ROCKWILL
Model NO. 12/24kV SF6 GIS for Secondary Distribution/Ring Main Unit
Rated voltage 12kV
Rated frequency 50/60Hz
Series RMR

Product descriptions from the supplier

Description
Description

A Ring Main Unit designed, manufactured and fully type-tested according to IEC 62271-200, RMR is widely used in power distribution systems, such as utilities, industries, buildings and new energy power stations.

This 12/24kV SF6 gas-insulated switchgear (GIS) is specifically engineered for secondary distribution networks and ring main unit applications. It integrates compact design with high reliability, utilizing SF6 gas insulation to ensure stable performance in harsh environments. Ideal for urban power grids, industrial parks, and commercial complexes, it supports efficient ring network distribution, enabling safe and continuous power supply with minimal footprint.

Key Features

  • SF6 Gas Insulation:Superior dielectric properties of SF6 gas ensure excellent insulation performance, withstanding high voltage and reducing the risk of flashovers, even in humid or dusty conditions.

  • Compact & Space-Saving:Slimmer cabinet design compared to air-insulated switchgear, saving up to 40% installation space—perfect for urban areas with limited room.

  • High Reliability for Ring Networks:Optimized for ring main unit topology, supporting looped power supply and rapid fault isolation to minimize downtime in secondary distribution systems.

  • Low Maintenance:Hermetic gas enclosure reduces leakage risks (≤0.1% per year) and extends maintenance intervals, lowering long-term operational costs.

  • Enhanced Safety:Equipped with internal arc protection (AFLR) and interlocking mechanisms to prevent unauthorized operation, ensuring personnel and equipment safety.

Parameters

  • SF6 gas-insulated switchgear

  • For secondary distribution

  • 12kV, 630A, 25kA

  • 24kV, 630A, 20kA

  • Customer Benefits:

  • Safe & Reliable

  • Maintenance free

  • Small in size

  • Easy to install

  • Smart function

Documentation Resource Library
Restricted
SEC SPECIFICATIONS FOR 11-33kV MV SPECIAL USE SMART RMU
Other
English
Consulting
Consulting
Restricted
Electric Du Cambodge Technical Specification for 22 kV Ring Main Units
Other
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025

Related Solutions

  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
  • Application of Intelligent Solid Insulated Ring Main Units (SIRMUs) in the Qinzhou Distribution Network
    1 IntroductionCoastal regions face environmental challenges including heavy rainfall, lightning, high temperatures, high humidity, and high salt spray corrosion. To ensure the safety of urban distribution grids in such environments, minimize power outages caused by equipment maintenance, and prevent accidents due to equipment end-of-life and other factors affecting grid security, we have researched the use of a new type of Solid Insulated Ring Main Unit (SIRMU). This SIRMU offers long lifespan,
    08/15/2025
  • SF₆ Ring Main Units (RMUs) and Urban Grid Renovation
    Overview​Older distribution networks are primarily radial in structure, with most incoming and outgoing lines being overhead lines. The switching equipment typically consists of air-insulated vacuum circuit breakers or minimal-oil circuit breakers. These networks suffer from frequent faults, high operating costs, and prolonged, widespread power outages in the event of a failure, significantly hindering economic development.With rapid economic growth and the implementation of urban grid renovatio
    08/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.