11kv Outdoor 35kv Prefabricated / Compact Substation Power Distribution Unit Box-Type Transformer Substation

  • 11kv Outdoor 35kv Prefabricated / Compact Substation Power Distribution Unit Box-Type Transformer Substation

Key attributes

Brand ROCKWILL
Model NO. 11kv Outdoor 35kv Prefabricated / Compact Substation Power Distribution Unit Box-Type Transformer Substation
Rated voltage 35kV
Rated frequency 50/60Hz
Series YBM

Product descriptions from the supplier

Description

Descripton

The YBM22 series prefabricated substation represents an integrated power distribution solution. It ingeniously combines high - voltage electrical equipment, transformers, and low - voltage electrical equipment into a compact, modular unit. Tailored for diverse application scenarios, it proves ideal for urban high - rise buildings, urban and rural infrastructure projects, residential communities, high - tech development zones, small and medium - sized factories, mining operations, oilfields, as well as temporary construction sites. Serving as a dependable and efficient option, it facilitates the reception and distribution of electrical energy within power distribution systems.

Key Features

  • Compact & Robust Design:The YBM22 series substation boasts a compact, space - saving structure. With a footprint just 1/10 to 1/5 of traditional substations, it drastically cuts design/construction workloads and overall project costs.

  • High Reliability & Safety:Engineered for stable, secure operation, it minimizes downtime and delivers strong performance even in harsh environments, ensuring power supply continuity.

  • Easy Maintenance & Mobility:Modular architecture simplifies upkeep. It also supports flexible relocation, suiting both permanent deployments (e.g., industrial parks) and temporary sites (e.g., construction projects).

  • Versatile Applications:Compatible with radial/terminal distribution networks, it integrates seamlessly into diverse power systems, adapting to varied operational needs (urban grids, industrial zones, etc.).

  • Standard Compliance:Aligned with GB/T 17467 - 1998 (national standard for HV/LV prefabricated substations), it guarantees top - tier performance and safety, meeting regulatory and reliability demands.

Technical Parameters

Advantages Over Conventional Substations

  • Space Efficiency:The compact structural design drastically cuts down the required installation area. It becomes the go - to choice for locations where space is at a premium, like crowded urban plots or sites with limited land availability.

  • Cost - Effectiveness:Compared with traditional substations, it slashes construction and installation expenses. From reduced civil engineering work to simplified on - site assembly, it trims costs at every stage of deployment.

  • Rapid Deployment:Thanks to prefabricated, modular components, the installation and commissioning processes are significantly accelerated. It can be quickly put into operation, shortening project timelines for urgent power - supply needs.

  • Scalability:It adapts seamlessly to diverse power distribution requirements, covering both small - scale setups (e.g., a single commercial building) and medium - scale projects (e.g., an industrial park). Modules can be added or adjusted as power demands evolve.

Applications

  • Urban & Rural Power Distribution Networks:Serves as a core power distribution node for city grids and rural power systems, optimizing power allocation in both densely - populated urban areas and dispersed rural regions.

  • Residential & Commercial Developments:Ideal for residential communities, shopping malls, office complexes, etc. Ensures stable power supply for daily living and commercial operations, matching the dense load characteristics of such scenarios.

  • Industrial Facilities:Supports power - intensive industrial sites like factories (manufacturing plants), mines (mining operations), and oilfields (petroleum extraction). Delivers reliable power to sustain continuous production processes.

  • Temporary Power Supply for Construction Sites:Meets the transient power needs of infrastructure projects (roads, bridges, buildings). Its easy - relocation design aligns with the dynamic nature of construction phases.

  • High - Tech & Development Zones:Provides stable, high - reliability power for technology parks, R & D centers, and innovation zones. Matches the strict power quality requirements of precision equipment and digital infrastructure.

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.