Description

SF6 ring main unit has the advantages of compact structure, fully enclosed type, fully insulated layer, long service life, maintenance-free, small indoor space occupation, and no environmental hazards during work. Widely used in industrial production and civil cable ring network and power supply system. It is very suitable for small and medium secondary substations, opening and closing stations, factories and mines, airports, railway lines, residential quarters, multi-storey buildings, highways, subway stations, tunnel construction and other industries.

Working environment conditions

  • Applicable altitude: 1000m
  • Applicable temperature: -40ºC~+45ºC
  • Relative humidity: daily average ≤95%, monthly average ≤90%
  • Earthquake damage level: ≤8

Structural features

  • Safe and reliable operation: Through multiple safety protection designs (such as a comprehensive interlocking mechanism and overload protection), it fully ensures the safety of the equipment during operation and running, effectively avoiding risks such as misoperation and short circuits. It builds a solid foundation for the continuous and stable operation of the power system, ensuring the continuity and reliability of power supply.
  • Integrated three-position load switch: Adopting an integrated three-position load switch (with three working positions: closing, opening, and grounding), it not only simplifies the internal structure and operation process of the equipment but also significantly improves the accuracy, coordination, and response speed of switch actions through precise mechanical linkage design. This reduces operational errors and enhances the stability of equipment operation.
  • Strong economic efficiency and durability: Achieves maintenance-free performance with high-quality materials and sealing technology, eliminating the need for frequent shutdowns for maintenance and reducing labor and material costs. Meanwhile, the equipment has high overall reliability, excellent anti-aging and anti-corrosion properties, and a service life of up to 20 years. This significantly reduces the frequency of equipment replacement and, in the long run, greatly lowers the full-life-cycle operating costs of the project.
  • Flexible and diverse solutions: Supports multiple incoming line modes such as left, right, upper, and forward incoming lines, which can be freely selected according to the on-site space layout. Unit combinations are not restricted, enabling complex combinations such as multi-unit series and parallel connections as needed. Combined with insulated busbar connection technology, it can flexibly build layout schemes of front-rear cabinets or left-right cabinets, perfectly adapting to the installation needs of different power distribution scenarios.
  • Wide design adaptability: The design scheme balances versatility and customization needs. It can not only meet the power distribution scenarios of conventional industrial plants and commercial buildings but also adapt to high-demand power distribution environments in special fields such as new energy power stations, rail transit, and data centers. With flexible and changeable structural design, it easily copes with personalized needs such as voltage levels and load capacities in different scenarios.
  • Efficient outgoing lines and space-saving: The outgoing line circuit design has a large capacity bearing capacity, which can meet the power output needs of high-power equipment. At the same time, it adopts a compact structural layout, minimizing the floor area while ensuring performance. It is especially suitable for scenarios with tight land resources such as urban core areas and industrial parks, achieving dual optimization of efficient power distribution and space utilization.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×