10.5kV 11kV 11.5kV 12kV Indoor Solid Insulated Ring Main Unit/RMU

  • 10.5kV 11kV 11.5kV 12kV Indoor Solid Insulated Ring Main Unit/RMU

Key attributes

Brand ROCKWILL
Model NO. 10.5kV 11kV 11.5kV 12kV Indoor Solid Insulated Ring Main Unit/RMU
Rated voltage 12kV
Rated frequency 50/60Hz
Series CKSS

Product descriptions from the supplier

Description
Description

Pioneer in China's eco-friendly switchgear sector, we have specialized in R&D and manufacturing of SF₆-free switchgear for decades. With core technologies, we have established industry standards. Boasting a fully independent end-to-end production chain, we have built a product matrix of zero-emission and high-reliability eco-friendly switchgear, making us a trusted choice for power grid construction.

10.5kV 11kV  11.5kV 12kV Indoor Solid Insulated Ring Main Unit:Based on a large amount of research on domestic and foreign markets, our company has independently absorbed the advanced technology in the industry, and independently developed a new generation of intelligent switchgear ssolid insulated ring main unit for the power distribution industry. It does not contain SF6 gas, novel structure, high performance, no inner arc, compact design, safety, environmental protection, maintenance-free, etc.

The ring main unit can be widely used in the field of intelligent power distribution network and urban power distribution.

Feature

  • Split-phase modular design;

  • The outer surface of the electrode is coated with a semiconductor layer and grounded;

  • The pressure relief port on the insulation box (switch room);

  • All solid insulation and sealing design;

  • Unique internal structure design;

  • Complete application solutions, free combination;

  • Smart application;

  • High altitude applications

Parameter

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

Color

silver or as request

Size

450*800*1450mm

Material

stainless steel, galvanized sheets

Rated voltage

12KV

Rated current

630A

Rated frequency

50HZ/60HZ

Type

solid insulated

Application

power distribution

Standard

IEC62271-200

Standard Operating Environment

  • Altitude: ≤2000 m (Special design adaptable to ≤2500 m)

  • Ambient Temperature: -15℃ to +40℃ (Short-term operation at ≤+50℃ for ≤4 hours within 24 hours is permissible)

  • Relative Humidity: Daily average ≤90%, monthly average ≤80% (Condensation-free and non-corrosive gas environment)


FAQ
Q: What are the key points to pay attention to during the maintenance of solid environmentally friendly cabinets?
A:
The core maintenance points include: 1) Regularly check the appearance of the solid insulation layer for cracks, deformation, discoloration or damage (especially focusing on conductor connections); 2) Avoid touching the insulation layer with sharp tools to prevent mechanical damage; 3) Monitor the temperature and humidity inside the cabinet to avoid high temperature and high humidity accelerating insulation aging; 4) Regularly test the insulation resistance to ensure that the insulation performance meets the standard; 5) Prevent the cabinet from being subjected to strong vibration or impact to avoid the insulation layer falling off.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.