• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


0~1500Hz High-performance frequency converters

  • 0~1500Hz High-performance frequency converters
  • 0~1500Hz High-performance frequency converters
  • 0~1500Hz High-performance frequency converters

Key attributes

Brand RW Energy
Model NO. 0~1500Hz High-performance frequency converters
Rated frequency 50/60Hz
Series HV510

Product descriptions from the supplier

Description

Overview

HV510 series frequency converter is a new generation of high-performance vector frequency converter, using a new high-performance open and closed loop vector control technology, supporting asynchronous motor and permanent magnet synchronous motor drive control; The high-quality, powerful performance and high-power density design enhance the advantages of ease of use, reliability, environmental adaptability, functional diversity, application flexibility in industrial applications, improve design standards and optimize installation space, etc., and upgrade the user experience in many aspects. It is widely used in metallurgy, lifting, petroleum, machine tools, plastics, metal products, papermaking, textile, printing and packaging and other automatic production equipment to drive.

Performance characteristics

Safe and reliable

  • Innovative independent air duct design

  • Efficient and accurate thermal simulation design

  • Rigorous temperature rise test and factory load aging

  • Automatic spraying process of conformal paint

  • Perfect fault protection function

High adaptability

  •  Wide grid adaptation design, -15%~+10%

  • Built-in C3 filter

  • EMC ground break design

  • Built-in brake unit design

  • Refined book-type design

Advanced control technology

  • V/F, open-loop vector, closed-loop vector control

  • Support drive asynchronous motor, permanent magnet synchronous motor

  • Support motor speed and torque mode control

  • Support two sets of motor parameter switching control

Excellent performance

  • Rich and comprehensive motor parameter self-identification ability

  • Perfect braking ability, support DC braking, energy consumption braking

  • Support various mainstream communication protocols: Profibus-DP, Profinet, etc.

  • Diversified expansion capabilities, I/O terminal cards, communication cards, etc

Featured app features

  • Output frequency up to 1500Hz

  •  Master-slave synchronous control function

  • Power failure restart function

  • Zero servo function

  • Swing frequency function

  • Encoder redundancy function

Autonomous and rapid commissioning

  • Background quick debugging software is available • Support frequency converter event recording and 12-channel oscilloscope recording

  • Support parameter editing, status monitoring, fault data and waveform download

Main parameters

project

Specifications and technical data

Input voltage

380V (-15%)~480V (+10%) three-phase

Input power frequency

50Hz/60Hz ±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0Hz~1500Hz

Motor type

Asynchronous motor, permanent magnet synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:100 V/F; 1:200 OLVC; 1:1000 CLVC

Start torque

VF:100%(0.5Hz);OLVC:150%(0.25Hz);CLVC:200%(0Hz)

Torque accuracy

±5% (OLVC, 5Hz and above), ±3% (CLVC)

Torque pulsation

≤ ±5%, under vector control mode

Steady speed accuracy

OLVC: 0.2%; CLVC :0.01%

Torque response

≤5ms, under vector control

acceleration and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150% 1min/5min, 200% 3s/5min for heavy duty applications; Light load application 110% 1min/5min, 150% 10s/5min

VF curve

Linear type, multi-point type, V/F semi-separation mode, V/F complete separation mode

Input frequency resolution

Digital setting: 0.01Hz ; Analog setting: Maximum frequency x 0.025%

acceleration and deceleration curves

linear and S-curve acceleration and deceleration mode; Four acceleration and deceleration times, one emergency stop deceleration time

Jogging control

In some applications, the frequency converter needs to run at low speed for a short period of time to facilitate testing the condition of the equipment

Torque control

Torque control is possible when vector controlled

Simple PLC, multi-terminal speed

16 speed operation is achieved through the control terminal

Built-in PID

It can be easily formed as a closed-loop control system

Virtual IO

8 virtual VDI/VDO and 3 AI DI for simple logic control

Overvoltage and overcurrent stall control

Automatic current and voltage limit during operation to prevent frequent overcurrent and overvoltage tripping

DC braking

Start the DC brake and stop the DC brake

Pre-excitation

The motor is pre-excited when the frequency converter is started, and the magnetic field is established inside the motor, which can effectively improve the torque characteristics during the start of the motor

Overexcitation

It can effectively suppress the rise of bus voltage during the deceleration process, avoid frequent overvoltage faults, and realize rapid braking to meet the rapid stop of power outages

RPM tracking

Both asynchronous and synchronous machines support speed tracking function; Vector control and V/F control both support speed tracking function

Protection function

Overvoltage suppression, undervoltage suppression, V/F overcurrent suppression, ground short circuit protection, phase loss protection, speed deviation detection, overvoltage protection, overcurrent protection, undervoltage protection, overload protection, overtemperature protection, start protection, bus undervoltage point setting, bus overvoltage point setting, etc

Documentation Resource Library
Restricted
High-Performance Inverter Selection catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: Can multiple motors be synchronized?
A:

Supports master-slave synchronous control, allowing multiple motors to start and stop together. The production line motor runs synchronously, with consistent speed, no lagging, high synchronization accuracy, and smoother production.

Q: Is the starting torque large or not?
A:

Under closed-loop vector control, the starting torque at 0Hz is 200%, while under open-loop control, it is 150%. Large fans reach their rated torque instantly during start-up, with fast start-up, high efficiency, no lag, and smoother operation.

Q: Where is the high frequency of 1500Hz used?
A:

Suitable for high-speed motor applications, such as machine tool spindles and high-speed centrifuges. The ordinary frequency converter reaches its limit at 500Hz, but this one can run at higher speeds, meet special process requirements, and has higher processing efficiency.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.