• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Design of Foundations of Transmission Towers in different Soils

Electrical4u
Field: Basic Electrical
0
China

Designing The Foundations Of Transmission Towers

Design of Foundation of Transmission Towers in Different Soils

  1. All foundation shall be of RCC. The design and construction of RCC structures shall be carried out as per IS:456 and minimum grade of concrete shall be M-20.

  2. Limit state method of design shall be adopted.

  3. Cold twisted deformed bars as per IS:1786 or TMT bars shall be used as reinforcement.

  4. Foundations shall be designed for the critical loading combination of the steel structure and or equipment and/or superstructure.

  5. If required protection to the foundation, shall be provided to take care of any special requirements for aggressive alkaline soil, black cotton soil or any soil which is detrimental/harmful to the concrete foundations.

  6. All structures shall be checked for sliding and overturning stability during both construction and operating conditions for various combination of loads.

  7. For checking against overturning, weight of soil vertically above footing shall be taken and inverted frustum of pyramid of earth on foundation should not be considered.

  8. Base slab of any underground enclosure shall also be designed for maximum ground water table. Minimum factor of safety of 1.5 against bouncy shall be ensured.

  9. The tower and equipment foundations shall be checked for a factor of safety of 2.2 for normal condition and 1.65 for short circuit condition against sliding, overturning and pullout.

Guidelines for Classification of Foundations of Transmission Towers in Different Soils

The transmission tower may be situated in different locations. Power System transmission networks are being sprading all over the world. The soil condition of different places are also different. Depending upon the nature of soil, the types foundation of transmission towers should be selected and constructed accordingly. We have tried to give you a clear and brief Guidelines for classification of Foundations of transmission towers in different Soil conditions.

SL

Name of soil encountered

Type of foundation to be adopted

1

In good soil (silty sand mixed with clay)

Normal Dry

2

Where top layer of Black Cotton soil extends upto 50% of the depth with good soil there after.

Partial Black Cotton

3

Where top layer of black cotton soil exceeds 50% and extends upto full depth or is followed by good soil.

Black Cotton

4

Where top layer is good soil upto 50% of the depth but the lower layer is a black cotton soil

Black Cotton

5

Where subsoil water is met at 1.5 ml or more below the ground level in good soil

Wet

6

Good soil locations which are in surface water for long period with water penetration not exceeding 1.0 m below ground level (e.g. paddy fields).

Wet

7

In good soil where subsoil water is encountered between 0.75m and 1.5m depth from ground level.

Partially submerged

8

In good soil where subsoil water is encountered within 0.75m depth from ground level

Fully Submerged

9

Where top layer of normal dry soil extends upto 85% of the depth followed by fissured rock without presence of water.

Dry Fissured Rock

10

Where top layer is lissured rock followed by good soil/sandy soil with/without presence of water

Special foundation

11

Where normal soil/tissured rock extends upto 85% of the depth followed by hard rock

Dry fissured Rock with under cut in Fisured Rock combined with anchor bar for hard rock design

12

Where fissure rock os encountered with subsoil water within 0.75m or below 0.75m from G.L. (Top layer may be either a good soil or black cotton soil)

Submerged Fissured Rock

13

Where Hard Rock is encountered at 1.5 m or less below ground level.

Hard Rock

14

Where Hard Rock is encountered from 1.5 m to 2.5m below G.L. (Top layer being good soil)

with chimney for Normal Soil Hard Rock Foundation

15

Where hard rock is encountered from 1.5m to 2.5 m below G./L. (Top layer either in Black cotton) soil or fissured Rock

Hard Rock Foundation design with chimneys designed for wet black cotton soil.

16

Where fissured rock is encountered at the bottom of pit (with black cotton soil at top)

Composite Foundation

17

Where hard rock is encountered at bottom with water and black cotton soil at top and hard rock layer depth is less than 1.5 m.

Hard Rock

18

Sandy soil with clay content not exceeding 10%

Dry Sandy soil

foudation

19

Sandy soil with water table in the pits

Wet sandy soil design to be developed considering the depth of water

20

Where top layer upto 1.5 m below G.L. is normal dry soil and thereafter hard soil/murrum

Normal dry with undercut

21

Where bottom layer is marshy soil with top layer of good soil/fissured rock/black cotton

Soil investigation is to be carried out and special foundation design to be developed.

22

Where the top layers are a combination of clinker mixed with firm soil, gravel and stone chips upto 60% of foundation deapth from ground level followed by hard murrum

Normal dry with undercut

23

Where top layers are combination of hard murrum, soft rock etc. followed by yellow/black clayee soil

Special foundation design is to be developed after carrying out soil investigation.

Any other combination of soil not covered above shall require development of special foundation design.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.