Tariff of Electricity in India

Electrical4u
Field: Basic Electrical
0
China

What Is The Tariff Of Electricity In India

Tariff refers to the amount of money the consumer has to pay for making the power available to them at their homes. Tariff system takes into account various factors to calculate the total cost of the electricity.
Before understanding tariff of electricity system in detail, a slight overview of the entire power system structure and hierarchy in India would be very fruitful. The
electrical power system mainly consists of generation, transmission and distribution. For generation of electrical power we have many PSUs and private owned Generating Stations (GS). The electrical transmission system is mainly carried out by central government body PGCIL (Power Grid Corporation of India Limited).
To facilitate this process, We divide India into five regions: Northern, Southern, Eastern, Western and Northeastern region. Further within every state, we have an SLDC (State Load Dispatch Center). The distribution system is carried out by many distribution companies (DISCOMS) and SEBs (State Electricity Board).

Types: There are two tariff systems, one for the consumer which they pay to the DISCOMS and the other one is for the DISCOMS which they pay to the generating stations.
Let us first discuss the tariff of electricity for the consumer i.e the cost consumer pay to the DISCOMS. The total cost levied on the consumer is divided into three parts usually referred as 3 part tariff system.

Here, a = fixed cost independent of the maximum demand and energy consumed. This cost takes into account the cost of land, labor, interest on capital cost, depreciation, etc.
b = constant which when multiplied by maximum KW demand gives the semi-fixed cost. This takes into account the size of
power plant as maximum demand determines the size of power plant.
c = a constant which when multiplied by actual energy consumed KW-h gives the running cost which8m takes into account the cost of fuel consumed in producing power.

Thus the total amount paid by the consumer depends on its maximum demand, actual energy consumed plus some constant sum of money.
Now electrical energy is expressed regarding unit, and 1 unit = 1 kW-hr (1 KW of power consumed for one hr).
IMPORTANT: All these costs are calculated on active power consumed. It is mandatory for the consumer to maintain a
power factor of 0.8 or above otherwise penalty is levied on them depending on the deviation.
Let us now discuss the tariff system existent in India for the DISCOMS. CERC (Central Electricity Regulatory Commission) regulates this. This tariff system is called availability based tariff (ABT).
As its name suggests, it is a tariff system which depends on the availability of power. It is a frequency based tariff mechanism which tends to make the power system more stable and reliable.
This tariff mechanism also has of 3 parts:

The fixed charge is same as that discussed above. The capacity charge is for making the power available to them and depends on the capacity of the plant, and the third one is UI. To understand the UI charges let us see the mechanism.

Mechanism of ABT

  • The generating stations commit a day ahead of the scheduled power which they can provide to the regional load dispatch center (RLDC).

  • The RLDC conveys this information to various SLDC which in turn collects the information from various state DISCOMS about the load demand from various types of consumers.

  • The SLDC sends load demand to RLDC, and now RLDC allocates the power accordingly to the various states.

If everything goes well, power demand is equal to power supplied and the system is stable and frequency is 50 Hz. But practically this rarely happens. One or more state overdraws or one or more GS under supplies and these lead to deviation in frequency and system stability. If demand is more than supply frequency that dips from the normal and vice verse.

UI charges are incentives provided or penalties imposed on the generating stations. If the frequency is less than 50 Hz, implies demand is more than supply, then the GS which supplies more power to the system than committed is given incentives. On the other hand, if the frequency is above 50 Hz, implying supply is more than demand, incentives are provided to GS for backing up the generating power. Hence it tries to maintain the system stable.

Time of Day: Usually during day period the demand for power is very high, and the supply remains the same. Consumers are discouraged to use excess energy by making the cost high. Contrary to that during night time, demand is less compared to supply, and hence consumers are encouraged to consume power by providing it at a cheaper rate. All these are done to make/keep the power system stable.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.