Quae sunt commodi et incommodi reclosure uniphasici et triphasic reclosure?

Echo
Campus: Analyse Transformatorem
China

Reclosure Uniphasica

Advantagium:

Cum defectus uniphasicus ad terram in linea occurrit et reclosure triphasica applicatur, maior tensiones transitoriae comparatae ad reclosure uniphasica resultant. Hoc quia interruptio trium phasium currentem interrumpit in transitu per zero, relinquit tensiones residuas in phasis non defectis—approximative aequales ad tensionem phasica maximam. Quia intervallo de-energizati in reclosure est relativum breve, tensio in his phasis non defectis non decrescit significanter, ducens ad substantialem tensionem transitoriam in reclosure. Contrariwise, cum reclosure uniphasica, tensio in phasi defecta momento reclosure est typice circa 17% nominale (propter divisionem capacitivam tensionis per lineam), sic evitans significantem tensionem transitoriam. Experientia operativa longi temporis cum reclosure triphasica in reticulis 110 kV et 220 kV demonstrat quod problemata tensionis transitoriae generaliter non sunt severa in lineis mediocris et brevibus.

Inconvenientia:

Cum reclosure uniphasica automatica utitur, operatio non pleniphasica occurrere potest. Praeter necessitatem specialis considerandorum pro protectione pilotali, hoc significanter affectat configurationem et coordinationem protectionis currentis zerophase, sic impedens protectionem currentis zerophase in lineis mediocris et brevibus a functionando efficaciter.
Reclosure Triphasica

Advantagium:

Cum reclosure triphasica utitur, circuitus disjunctores omnium protectionum relatorum directe actuat disjunctorem. Tamen, cum reclosure uniphasica automatica utitur, omnes protectiones pilotales, protectiones distanciarum interphasicae, protectiones currentis zerophase, etc.—praeter eas inherentemente possidentes capacitate selectionis phasica—debeant controlari ab elemento selectionis phasicae reclosoris uniphasici antequam possint actuate disjunctorem.

Inconvenientia:

Cum reclosure triphasica utitur, sub pessimis conditionibus, reclosure potest occurrere super defectum triphasicum. In certis lineis ubi studia stabilitatis indicant quod talis reclosure debebitur evitari, elementum simpliciter detectivum defectus interphasici ad schemata reclosure triphasica addi potest. Hoc elementum prohibet reclosure pro defectibus interphasici, permittens tamen reclosure pro defectibus uniphasici.

Donum da et auctorem hortare

Suggestus

Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
02/05/2026
Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem