Secondary control circuit diagram of isolation switch and ground switch in 110kV combined electric

Master Electrician
Master Electrician
Field: Basic Electrical
0
China

Secondary control circuit diagram of isolation switch and ground switch in combined electric

屏幕截图 2024-10-12 150918.jpg

SP:Limit device

CX:Closing contactor

SFA:selector switch

SFB:selector button

89KT:Thermal relay

TX:Dc switching contactor

Give a tip and encourage the author!
Recommended
Outdoor Substations: Types, Pros & Cons (55kV–765kV)
Outdoor Substations: Types, Pros & Cons (55kV–765kV)
Substations designed for voltage levels ranging from 55 kV to 765 kV are known as outdoor substations. This type of substation requires less construction time but occupies more space. Outdoor substations are mainly divided into pole-mounted substations and foundation-mounted substations.Pole-Mounted SubstationsThis type of substation is used to support distribution transformers with capacities up to 250 kVA. Such transformers represent the cheapest, simplest, and smallest form of distribution. A
Edwiin
11/06/2025
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
Handling 35kV Substation Fault Tripping
Handling 35kV Substation Fault Tripping
Analysis and Handling of Fault Tripping in 35kV Substation Operation1. Analysis of Tripping Faults1.1 Line-Related Tripping FaultsIn power systems, the coverage area is extensive. To meet power supply demands, numerous transmission lines must be installed—posing significant management challenges. Especially for special-purpose lines, installations are often located in remote areas such as suburbs to minimize impact on residential life. However, these remote areas have complex environments, makin
Leon
10/31/2025
 Analysis of Substation Busbar Discharge Faults and Their Solutions
Analysis of Substation Busbar Discharge Faults and Their Solutions
1. Methods for Detecting Busbar Discharge1.1 Insulation Resistance TestThe insulation resistance test is a simple and commonly used method in electrical insulation testing. It is highly sensitive to through-type insulation defects, overall moisture absorption, and surface contamination—conditions that typically result in significantly reduced resistance values. However, it is less effective in detecting localized aging or partial discharge faults.Depending on the equipment’s insulation class and
Edwiin
10/31/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.