Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
A Brief Analysis of Maintenance and Management of High-Voltage Disconnectors
High-voltage disconnectors are widely used in China’s power systems due to their convenient operation and strong practicality. However, during long-term operation, serious faults such as insulator fracture and failure to open/close still occur, significantly impacting the normal operation of power systems [1]. Based on this, this paper analyzes common faults of high-voltage disconnectors during operation and proposes corresponding solutions based on actual working conditions to improve managemen
11/15/2025
Consult
Tip
Consult
Tip
A Brief Discussion on the Retrofit and Application of Stationary Contacts in 220 kV Outdoor High-Voltage Disconnectors
The disconnector is the most widely used type of high-voltage switching equipment. In power systems, high-voltage disconnectors are high-voltage electrical devices used in coordination with high-voltage circuit breakers to perform switching operations. They play a critical role during normal power system operation, switching operations, and substation maintenance. Due to their frequent operation and high reliability requirements, disconnectors significantly impact the design, construction, and s
11/14/2025
Consult
Tip
Consult
Tip
Abnormal Operation and Handling of High-Voltage Circuit Breakers and Disconnectors
Common Faults of High-Voltage Circuit Breakers and Mechanism Pressure LossCommon faults of high-voltage circuit breakers themselves include: failure to close, failure to trip, false closing, false tripping, three-phase asynchronism (contacts not closing or opening simultaneously), damage to the operating mechanism or pressure drop, oil spraying or explosion due to insufficient interrupting capacity, and phase-selective circuit breakers failing to operate according to the commanded phase."Circuit
11/14/2025
Consult
Tip
Consult
Tip
ABB adds Ethernet-APL connectivity to electromagnetic flowmeters for hazardous areas
ABB adds Ethernet-APL connectivity to electromagnetic flowmeters for hazardous areasProcessMaster, ABB’s next-generation electromagnetic flowmeter, now enables high-speed field data transmission in hazardous environments.Sensors with Ethernet-APL support combine precise measurement with fast, secure data access, bringing significant changes to the chemical, oil and gas, power, and water industries.ABB’s continuously expanding portfolio of instruments with Ethernet-APL connectivity opens new poss
11/14/2025
Consult
Tip
Consult
Tip
High-Voltage Technology: Can a high-voltage circuit breaker motion characteristic tester measure with dual-ended grounding?
Can dual-ended grounding be measured?Dual-ended grounding can be measured, but traditional high-voltage circuit breaker motion characteristic testers cannot perform such measurements. The conditions for dual-ended grounding are relatively complex; measurement accuracy must be ensured while simultaneously dealing with numerous electromagnetic interferences such as impedance and high-frequency currents. Therefore, a high-voltage circuit breaker tester specifically designed for dual-ended grounding
11/14/2025
Consult
Tip
Consult
Tip
Measures to Ensure Zero Busbar Voltage Loss in Substations
I. IntroductionSubstations serve as critical hubs in power systems, responsible for transmitting electrical energy from power plants to end users. Busbars, as a key component of substations, play an essential role in power distribution and transmission. However, busbar voltage loss incidents occur from time to time, posing a serious threat to the safe and stable operation of power systems. Therefore, ensuring zero busbar voltage loss in substations has become a crucial issue in power system oper
11/14/2025
Consult
Tip
Consult
Tip
Advantages and Disadvantages of Double-Busbar Configuration in Substations
Advantages and Disadvantages of Double-Busbar Configuration in SubstationsA substation with double-busbar configuration employs two sets of busbars. Each power source and each outgoing line is connected to both busbars via one circuit breaker and two disconnectors, allowing either busbar to serve as the working or standby busbar. The two busbars are interconnected through a bus tie circuit breaker (referred to as the bus coupler, QFL), as shown in the figure below.I. Advantages of Double Busbar
11/14/2025
Consult
Tip
Consult
Tip
Development of a Lifting Device for High-Voltage Disconnectors in Complex Environments
In power systems, high-voltage disconnectors in substations have suffered from aging infrastructure, severe corrosion, increasing defects, and insufficient current-carrying capacity of the main conductive circuit, significantly compromising power supply reliability. There is an urgent need to carry out technical retrofits on these long-in-service disconnectors. During such retrofits, to avoid interrupting customer power supply, the common practice is to place only the retrofit bay under maintena
11/13/2025
Consult
Tip
Consult
Tip
Corrosion and Protective Practices of High-Voltage Disconnectors
High-voltage disconnectors are extremely widely used, and therefore people pay great attention to potential problems that may arise with them. Among various faults, corrosion of high-voltage disconnectors is a major concern. In light of this situation, this article analyzes the composition of high-voltage disconnectors, types of corrosion, and faults caused by corrosion. It also investigates the causes of disconnector corrosion and studies theoretical foundations and practical techniques for cor
11/13/2025
Consult
Tip
Consult
Tip
Faults and Handling Measures for 220 kV Outgoing Circuit Breakers and Disconnectors
1. Significance of Enhancing Fault Handling for 220 kV Outgoing Circuit Breakers and Disconnectors220 kV transmission lines are highly efficient and energy-saving high-voltage power transmission systems that significantly benefit daily life. A fault in a circuit breaker can severely compromise the safety and reliability of the entire power grid. As critical components of high-voltage transmission systems, circuit breakers and disconnectors play essential roles in power flow control and fault pro
11/13/2025
Consult
Tip
Consult
Tip
Send inquiry