Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
07/30/2025
Consult
Tip
Consult
Tip
Real-Time Monitoring of Surge Arresters in 10kV GIS Cubicles: Enhancing Railway Power System Safety
1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo en
07/30/2025
Consult
Tip
Consult
Tip
Advancements in Electromagnetic Induction-Based Cable Eccentricity Measurement: Overcoming Jitter and Enhancing Precision
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter,
07/29/2025
Consult
Tip
Consult
Tip
Intelligent Device for Insulation Restoration of Low-Voltage Overhead Cables: Automated, Efficient, and Precise Solutions
1. Current Situation and ProblemsLow - voltage overhead cables often suffer insulation damage. Urbanization and infrastructure construction expose them to complex environments (construction, severe weather like strong winds/rains causing scratches or impacts, animal damage), easily breaking insulation layers. Long - term operation also degrades insulation due to aging, corrosion, and prolonged sunlight—e.g., cables in old communities age and crack, raising failure risks.Existing restor
07/29/2025
Consult
Tip
Consult
Tip
Optimized Cable Laying and Wiring Construction Technology for Photovoltaic Power Stations: A BIM-Based Approach
1 Research on Cable Laying and Wiring Construction Technology of Photovoltaic Power Station1.1 Data CollectionBefore constructing the BIM model for cable laying, it is necessary to deeply master the detailed parameters of the involved equipment specifications, materials used in construction, and site conditions, aiming to improve the accuracy of model construction. To ensure that the BIM model can accurately reflect the actual situation of the construction site, the core lies in accurately colle
07/29/2025
Consult
Tip
Consult
Tip
Optimizing Cable Detection and Performance in Intelligent Building Wiring Systems
The integrated wiring system of intelligent buildings, as the core carrier of information transmission, functions like a "nervous system." It connects signals such as voice, data, and images, enabling device interconnection and efficient information transmission. Cable detection is a key link to ensure system performance and information security, focusing on index detection, problem troubleshooting, and response measures.1. Core Cable Detection Indicators1.1 Appearance and Identification Verific
07/29/2025
Consult
Tip
Consult
Tip
Ensuring Stability and Safety in Communication Cable Installation for Protective Spaces
In the context of deep integration of informatization and intelligence, protective spaces, as core carriers of critical communication systems, their stability and safety directly impact information transmission reliability and infrastructure operational efficiency. Thus, analyzing core difficulties (environmental adaptability matching, electromagnetic compatibility design, construction precision control) in communication cable installation in protective spaces holds significant engineering value
07/29/2025
Consult
Tip
Consult
Tip
Process Improvement for Consistent Transformer Manufacturing: Inductance Control & Performance Optimization
Given the lack of manufacturers for such transformers on the market, we design them in - house. We provide technical specs to partners, specifying materials like high - temp enameled wires.Electrical signals from downhole logging tools, transmitted via these transformers, impact formation - to - surface signal reliability. Thus, improving transformer consistency boosts signal uniformity, enhancing logging tool accuracy and our market competitiveness.Our common signal transformers are EI - type,
07/28/2025
Consult
Tip
Consult
Tip
Managing Microbial Contamination in Specialty Transformer Oil: Causes, Effects, and Treatment Methods
1 OverviewCases of transformer oil contaminated by microorganisms have been reported both domestically and internationally. Individual transformer manufacturers, user units, and research institutions have conducted specialized studies, but all focused on power transformers. This paper targets specialty transformers for specific applications (e.g., rectifier transformers for graphitization furnaces, submerged arc furnace transformers), exploring the process of microbial contamination of their tra
07/28/2025
Consult
Tip
Consult
Tip
Solving the Contradiction in Arc Suppression Coil Grounding: Damping Resistor Applications and Tuning Strategies
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should b