Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Revolutionary 550 kV Capacitor-Free Arc-Quenching Circuit Breaker Debuts in China
Recently, a Chinese high-voltage circuit breaker manufacturer, in collaboration with numerous renowned enterprises, successfully developed a 550 kV capacitor-free arc-quenching chamber circuit breaker, which has passed the full suite of type tests on its first attempt. This achievement marks a revolutionary breakthrough in the interrupting performance of circuit breakers at the 550 kV voltage level, effectively resolving the long-standing “bottleneck” issue caused by reliance on imported capacit
11/17/2025
Consult
Tip
Consult
Tip
Abnormal Operation and Handling of High-Voltage Circuit Breakers and Disconnectors
Common Faults of High-Voltage Circuit Breakers and Mechanism Pressure LossCommon faults of high-voltage circuit breakers themselves include: failure to close, failure to trip, false closing, false tripping, three-phase asynchronism (contacts not closing or opening simultaneously), damage to the operating mechanism or pressure drop, oil spraying or explosion due to insufficient interrupting capacity, and phase-selective circuit breakers failing to operate according to the commanded phase."Circuit
11/14/2025
Consult
Tip
Consult
Tip
High-Voltage Technology: Can a high-voltage circuit breaker motion characteristic tester measure with dual-ended grounding?
Can dual-ended grounding be measured?Dual-ended grounding can be measured, but traditional high-voltage circuit breaker motion characteristic testers cannot perform such measurements. The conditions for dual-ended grounding are relatively complex; measurement accuracy must be ensured while simultaneously dealing with numerous electromagnetic interferences such as impedance and high-frequency currents. Therefore, a high-voltage circuit breaker tester specifically designed for dual-ended grounding
11/14/2025
Consult
Tip
Consult
Tip
Faults and Handling Measures for 220 kV Outgoing Circuit Breakers and Disconnectors
1. Significance of Enhancing Fault Handling for 220 kV Outgoing Circuit Breakers and Disconnectors220 kV transmission lines are highly efficient and energy-saving high-voltage power transmission systems that significantly benefit daily life. A fault in a circuit breaker can severely compromise the safety and reliability of the entire power grid. As critical components of high-voltage transmission systems, circuit breakers and disconnectors play essential roles in power flow control and fault pro
11/13/2025
Consult
Tip
Consult
Tip
The world's first 800 kV / 80 kA circuit breaker has passed national-level technical appraisal.
On November 9, a new type of circuit breaker for gas-insulated metal-enclosed switchgear—designated ZF27-800(L)/Y6300-80—successfully passed a national-level technical appraisal organized by the Chinese Society for Electrical Engineering (CSEE) in Beijing. Developed jointly by a leading Chinese manufacturer of gas-insulated metal-enclosed switchgear and multiple partner institutions, this world-first 800 kV, 80 kA circuit breaker, featuring full independent intellectual property rights, has achi
11/13/2025
Consult
Tip
Consult
Tip
Improved Interlock Wiring for Isolator Safety
Interlocking the disconnector (isolator) control wiring with its associated circuit breaker can effectively prevent the inadvertent opening or closing of the disconnector under load. However, during operations involving bus-side and line-side disconnectors, human error may lead to an incorrect sequence of operations—an action strictly prohibited by switching principles and a known cause of power system accidents.To prevent such sequence errors, for substations and power plants that do not employ
11/11/2025
Consult
Tip
Consult
Tip
What are the causes of dielectric withstand failure in vacuum circuit breakers?
Causes of Dielectric Withstand Failure in Vacuum Circuit Breakers: Surface contamination: The product must be thoroughly cleaned before dielectric withstand testing to remove any dirt or contaminants.Dielectric withstand tests for circuit breakers include both power-frequency withstand voltage and lightning impulse withstand voltage. These tests must be performed separately for phase-to-phase and pole-to-pole (across the vacuum interrupter) configurations.Circuit breakers are recommended to be t
11/04/2025
Consult
Tip
Consult
Tip
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
11/04/2025
Consult
Tip
Consult
Tip
The 8-Phase Guide to Installing LW25-126 High-Voltage Circuit Breakers Correctly
1. Pre-Installation PreparationsBefore commencing installation work, the following preparatory steps must be completed: Organization and Training: Organize training sessions for all construction personnel on relevant regulations,technical standards, and construction procedures. Special emphasis should be placed on safety protocols. Site Survey: Examine the intended location of the circuit breaker, its foundation, and the layout of surrounding equipment and wiring to prevent accidental contact wi
10/29/2025
Consult
Tip
Consult
Tip
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
10/28/2025
Consult
Tip
Consult
Tip