• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Mesh Current Analysis Method
The Mesh Current Analysis Method is utilized to analyze and solve electrical networks with multiple sources or circuits comprising numerous meshes (loops) containing voltage or current sources. Also known as the Loop Current Method, this approach involves assuming a distinct current for each loop and determining the polarities of voltage drops across loop elements based on the assumed direction of the loop current.In mesh current analysis, the unknowns are the currents in different meshes, and t
06/02/2025
Consult
Tip
Consult
Tip
Nodal Voltage Analysis Method
Nodal Voltage AnalysisNodal voltage analysis is a method for solving electrical networks, particularly useful when all branch currents need to be computed. This approach determines voltages and currents by leveraging the nodes of a circuit.Anodeis a terminal where three or more circuit elements connect. Nodal analysis is commonly applied to networks with multiple parallel circuits sharing a common ground terminal, offering the advantage of requiring fewer equations to solve the circuit.Principle
06/02/2025
Consult
Tip
Consult
Tip
Series Magnetic Circuit
Definition of Series Magnetic CircuitDefinition: A series magnetic circuit is defined as a magnetic pathway composed of multiple sections with varying dimensions and materials, all carrying the same magnetic field. Consider a circular coil or solenoid with distinct dimensional parameters, as illustrated in the figure below:Series Magnetic Circuit AnalysisA currentIflows through a solenoid withNturns wound around one section of a circular coil, inducing a flux Φ in the core. a₁, a₂, a₃: C
05/28/2025
Consult
Tip
Consult
Tip
What is an AC Circuit?
AC Circuit FundamentalsAn AC circuit is defined as a circuit energized by an alternating power source. Alternating current (AC) is widely used for domestic and industrial applications due to its unique characteristics: unlike DC, both the magnitude and direction of current and voltage in an AC circuit vary periodically over time.AC waveforms typically follow a sinusoidal pattern, completing one cycle with equal positive and negative halves. This behavior is mathematically described as a function
05/27/2025
Consult
Tip
Consult
Tip
500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
05/21/2025
Consult
Tip
Consult
Tip
Research on the Application Mode and Operation Monitoring of Tank-type Circuit Breaker Heating Tapes in 500kV Substations in High-Cold Areas
At present, most low - voltage switchgear assemblies in China mainly use SF₆ gas at a pressure of 0.5 - 0.6 MPa as the insulating medium. However, when the ambient temperature drops to around - 32.5°C, the SF₆ gas will quickly liquefy, resulting in serious problems with the insulation and interrupting capabilities of the product. To avoid affecting the operation of low - voltage switchgear assemblies in alpine regions, tracing heaters are often used to prevent the liquefaction of SF₆ gas
05/21/2025
Consult
Tip
Consult
Tip
Research on Detection Technology and Analysis Method of Partial Discharge in SF6 Floor Tank Circuit Breaker
The floor - mounted tank - type circuit breaker is a crucial control and protection device in substations and power systems. It is mainly used to interrupt, close, and carry normal load currents in lines, and to cut off short - circuit currents during system failures. Composed of components such as interrupting elements, insulating bushings, bushing - type current transformers, arc - extinguishing chambers, operating mechanisms, and grounding casings, the arc - extinguishing chamber of the floor
05/21/2025
Consult
Tip
Consult
Tip
Discussion on the Problem of Gas Liquefaction during the Installation of Tank Circuit Breakers in Severe Cold Regions
Technical Explanation of Sulfur Hexafluoride (SF₆) Circuit Breakers and Gas Liquefaction ChallengesSF₆ circuit breakers, which use sulfur hexafluoride gas—known for its excellent arc-quenching and insulating properties—as the arc-extinguishing medium, are widely applied in power systems. These breakers are suitable for frequent operations and scenarios requiring high-speed interruption. In China, SF₆ circuit breakers are basically used for voltage levels of 110kV and above. H
05/21/2025
Consult
Tip
Consult
Tip
Design and Application Case of 252kV Dead Tank SF6 Circuit Breaker Arc - Quenching Chamber System
IntroductionIn recent years, Nigeria's power demand has been on the rise with the development of its economy and society. A stable and reliable power transmission system is crucial for its development. The 252kV high - voltage transmission lines play an important role in Nigeria's power grid, and the performance of circuit breakers directly affects the safety and stability of these lines. ABB, as a world - leading electrical equipment manufacturer, has developed a 252kV dead tank SF6 circuit bre
05/21/2025
Consult
Tip
Consult
Tip
Scheme Design of Three-phase Mechanical Transmission for 252kV Tank-type High-voltage sulfur Hexafluoride Circuit Breaker
Design and Application of Three-Phase Mechanical Linkage for 252kV Tank-Type SF₆ Circuit Breakers in China's High-Voltage Power GridIn China's high-voltage transmission network, three-phase power transmission systems are universally adopted, with high-voltage electrical equipment also configured in three-phase layouts. Most existing 252kV tank-type SF₆ circuit breakers feature phase-separated designs, where each phase is equipped with an independent motor-spring operating mechanism. Three-phase
05/20/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.