12‑17.5 kV indoor load‑break‑switch, rated current 125‑630A, peak short‑circuit making‑current 50kA, fuse‑triggered tripping function, pneumatic‑actuated for indoor medium‑voltage distribution cabinets.

Add us on Google
Updated2026.09
LanguageEnglish
FilePDF · 122.8 KB
Load SwitchHV Load Switch
Download

Document description

This PDF product flyer supports tender comparison, indoor‑distribution‑project selection and pre‑sales technical evaluation. This indoor medium‑voltage load‑break‑switch complies with IEC 62271‑1 general high‑voltage switchgear requirements and IEC 62271‑103 for AC switches from 1 kV up to 52 kV.

It adopts three‑phase modular pneumatic actuator with simple construction and backup manual‑operation function for 50 Hz grid application. This datasheet records phase‑to‑phase / phase‑ground and isolating‑gap lightning & power‑frequency dielectric‑withstand values, thermal‑dynamic stability ratings for main unit and earthing‑switch, no‑load‑transformer breaking‑capacity, cable‑charging breaking‑current, transfer‑current, mechanical‑life and fast fuse‑triggered tripping‑time below 0.06 s.

Control circuit supports AC/DC 110 V and 220 V power supply. It is supplied with complete standard‑accessories for diversified indoor installation scenarios. Custom‑manufacturing services covering design adjustment, assembly and project‑specific factory‑acceptance‑test are available for indoor distribution‑grid projects. Please contact us for complete dimension drawings and full set of type‑test reports.

Related Products

Frequently asked questions

Custom‑made services include parameter adjustment, functional‑module combination optimisation and project‑specified factory‑acceptance‑test‑items. Please contact us to submit your technical‑specification.

It covers interrupting no‑load transformer capacity, cable‑charging breaking‑current and transfer‑current for common ring‑main‑unit application‑scenarios. Please contact us for application‑boundary guidance.

Higher isolating‑gap withstand‑value guarantees sufficient insulation strength on visible open‑position, securing operator safety during equipment‑maintenance work. Please contact us for insulation‑co‑ordination advice.