Indoor AC High-Voltage Load break Switch-10kV to 12kV
Brochure · ROCKWILL

Indoor AC High-Voltage Load break Switch-10kV to 12kV

12 kV indoor AC load‑break switch, rated current 400‑630A, 4‑second short‑time withstand current 12.5‑20kA, peak short‑circuit making‑current 31.5‑50kA, pneumatic actuator, multiple functional variants for indoor medium‑voltage distribution system.

Add us on Google
Updated2026.09
LanguageEnglish
FilePDF · 147.7 KB
HV LBS
Download

Document description

This PDF product flyer supports tender comparison, indoor‑distribution‑project selection and pre‑sales technical evaluation. This indoor medium‑voltage load‑break‑switch complies with IEC 62271‑1 general high‑voltage switchgear requirements and IEC 62271‑103 for AC switches from 1 kV to 52 kV.

It adopts three‑phase modular pneumatic actuator with simple construction and backup manual‑operation function, delivering stable performance under 50 Hz grid condition and achieving up to 30 000 overhaul‑free mechanical operations.

This datasheet records phase‑to‑phase / phase‑ground and isolating‑gap dielectric withstand values, thermal‑dynamic stability parameters, and provides configurable variant options including outgoing‑side earthing switch, mechanical interlock, fuse assembly and electric tripping device, together with complete standard‑accessory sets adapting diversified indoor installation requirements.

Custom‑manufacturing services covering design adjustment, assembly and project‑specific factory‑acceptance‑test are available for indoor distribution‑grid projects. Please contact us for complete dimension drawings and full set of type‑test reports.

Related Products

Frequently asked questions

Matching standard‑accessories simplify cabinet‑assembly work, reduce additional component‑procurement and guarantee installation‑quality inside switch‑cubicles. Please contact us for accessory‑list reference.

Outgoing‑side earthing‑switch reliably grounds load‑side conductors after opening, forming safe working‑condition for equipment overhaul and inspection. Please contact us for operation‑precaution tips.

It supports outgoing‑side earthing‑switch, mechanical interlock device, different‑type fuse units and electric opening‑device for diversified cabinet‑solution requirements. Please contact us for variant‑selection guide.

Comments

Share your question or perspective
WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register