• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


ZMZ-B series integration power capacitor

  • ZMZ-B series integration power capacitor

Key attributes

Brand Switchgear parts
Model NO. ZMZ-B series integration power capacitor
Rated voltage 450V
Rated frequency 50Hz
Series ZMZ-B

Product descriptions from the supplier

Description

Application

ZMZ-B series intellect integration power capacitor is new reactive compensation equipment which is 0.4 kv low voltage distribution electric net, high save power, reduce wire loss, improve power factor and power quality .it make up by intellect testing unit over zero input switch circuit and protect unit, two pcs (△) or one pc(Y) low voltage capacitor .this capacitor replace for low voltage power capacitor which is make up by intellect controller fuse and combine switch or contactor, thermal relay .low voltage power capacitor indicate lighting and other component of bank which connetc one conductor make up to auto reactive compensate equipment . It change tradition reactive compensate big volume and very strong instruction mode. So new power capacitor has good compensate function, low volume, low power loss, good price, save cost, and using convenient, maintain is easy and long life, reliability is best, it suitable modern intellect electric net reactive compensate demanding.

Product function

1. Small volume ,easy installation, it can field intellect compensate according to products ,only miss up connectionsign it will auto cut at once

2. One products auto intellect ,or some products connect net to intellect ,

3. Integration capacitor can show power factor electric net voltage, electric net second time current ,products temperatureand products faulty

4. It can set input power factor according to the in fact condition ,ablate voltage setting

Working conditions

1. Condition: altitude 2000 m, temperature -25℃+50℃; Relative humidity 20℃,≤90%

2. Rated voltage: 250VAC、50Hz

3. Rated capacity: share compensate: 5-40kvar sub compensate: 5-20kvar

4. Capacity tolerance : -5+10%

5. Most permit over voltage: 110% rated voltage

Compensation mode Model Specification Capacity(kvar) Voltage(V)
Three-phase compensation ZMZ-DS/450-5-B 5 450
  ZMZ-DS/450-10-B 10 450
  ZMZ-DS/450-15-B 15 450
  ZMZ-DS/450-20-B 20 450
  ZMZ-DS/450-25-B 25 450
  ZMZ-DS/450-30-B 30 450
Split-phase compensation ZMZ-DF/280-5-B 5 250
  ZMZ-DF/280-10-B 10 250
  ZMZ-DF/280-15-B 15 250
  ZMZ-DF/280-20-B 20 250

Outline & installation size

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.