• YZ Series Point type oil level indicator of transform
  • YZ Series Point type oil level indicator of transform
YZ Series Point type oil level indicator of transform
discuss personally
Model
YZF-100
YZF-120
YZF-140
YZF2-175
YZF2-200
YZF-200
YZFS2-250/YZB-250
YZF-250
YZF2-250
Basic info
Brand Transformer Parts
Model NO. YZ Series Point type oil level indicator of transform
Dial diameter 250
Installation diameter 140
Series YZ Series
Product Detail

Overview

YZ series point type oil level indicators are used for oil level indication of conservators of transformer and on load tap changer as well as oil level indication of various pressure and open type containers. The oil level indicator is not only is not only used for local indication but also can be used for remote control because it is provided with signal output of higher and lower oil level alarming. According to the JB/T 10692-2007 production.

 

Technology parameters

1.working temperature:-30℃~50℃

2.switch capacity:DC220 0.3A ; AC220 1A

3.Sealing performance:

Seal performance: Without leakage and deformation under the oil pressure of 0.3Mpa

5.YZF oil level indicator installatoin size simple list

 Type

φP

α

H

D

d

n - φx

α1

α2

φn xφ

YZF2 - 250

250

270°

170

156

130

6 - φ12

45°

20°

φ115 x 6

YZF - 250

250

270°

170

195

170

6 - φ12

45°

20°

φ152 x 8

YZF - 200

200

270°

155

195

170

6 - φ12

120°

20°

φ152 x 8

YZF2 - 200

200

120°

155

160

135

6 - φ12

120°

20°

φ115 x 5

YZF3 - 200

200

270°

155

160

135

6 - φ12

45°

20°

φ115 x 5

YZF2 - 175

175

120°

100

210

170

4 - φ18

60°


YZF - 140

140

120°

85

140

116

4 - φ13

120°

φ100 x 7

YZF3 - 140

140

270°

160

140

116

4 - φ13

45°

20°

φ100 x 7

YZS2 - 250

(YZB - 250)

250

270°

160

140

116

4 - φ13

 45°

20°

φ152 x 8

YZF - 120

120

120°

26

120

108

4 - φ6

120°

φ108 x 6

YZF - 100

100

120°

25

100

88

3 -φ7

120°

φ88 x 7

 

If you need to know about more parameters , Please check the model selection manual.↓↓↓ 

Know your supplier
Transformer Parts
As a key component in power systems, the stable operation of transformers relies on high-quality accessories. Wone specializes in the sales and supply of transformer accessories, delivering high-quality products and fast response services through an efficient and professional supply chain system. Core Strengths Comprehensive Product Range: Includes insulation materials, cooling components, protection devices, and various structural parts to meet diverse needs. Global Supply Chain Network: Integrates high-quality supplier resources to ensure product stability and reliable delivery schedules. Smart Logistics Management: Utilizes information systems for full-process tracking, improving delivery efficiency and transparency. Professional Technical Support: Offers product selection advice, application consulting, and after-sales maintenance to ensure smooth project execution. Commitment to Sustainability: Prioritizes eco-friendly materials and energy-efficient products, fulfilling corporate social responsibility. Wone is committed to building an efficient, reliable, and sustainable supply chain for transformer accessories, supporting the stable development of the power industry.
Main Categories
Electrical fittings
Business Type
Design/Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
transformer parts selection manual
White paper English
Consulting
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!