VSR8 Series Single Phase Solid State Relay

  • VSR8 Series Single Phase Solid State Relay
  • VSR8 Series Single Phase Solid State Relay
  • VSR8 Series Single Phase Solid State Relay

Key attributes

Brand MV Switchgear Accessories
Model NO. VSR8 Series Single Phase Solid State Relay
Rated normal current 25A
Series VSR8

Product descriptions from the supplier

Description
VSR8 series single-phase solid-state relay product features:
The VSR8 series has become an ideal choice in the following fields due to its stability and anti-interference ability:
1. Industrial control: CNC machine tools, rubber and plastic machinery, electric furnace constant temperature system, automated production line
2. Energy management: electric heating devices, power switching systems, reactive power compensation equipment
3. Public facilities: traffic signals, intelligent lighting systems, stage lighting control
4. Precision equipment: medical instruments, analytical instruments, printing equipment, fire control systems
5. Livelihood areas: commercial appliances, office automation equipment, security systems
VSR8 series single-phase solid-state relay product features:
1. Strong load compatibility
Current coverage from 15A to 120A (7 levels optional)
Voltage support for multiple ranges: 24-280VAC/24-480VAC/48-660VAC
2. Flexible trigger mode
Zero crossing conduction: suppresses startup shock and protects inductive/capacitive loads
Random conduction: meets the instantaneous switching requirements
3. Strengthen protective design
Industrial grade insulation performance (4000VACrms)
Removable protective cover enhances maintenance convenience
Advantages of VSR8 series single-phase solid-state relay products:
1. High security:
The dielectric withstand voltage reaches 4000VACrms, with a built-in IP20 protective removable cover plate to ensure safe operation
2. Strong adaptability:
Supports wide control voltage (3-32VDC/90-280VAC) to simplify system integration
3. Intelligent control:
Optional zero crossing conduction (reducing surge current) or random conduction (immediate response) mode
4. Status visualization:
The LED indicator light displays the running status in real time, making it easy to troubleshoot
5. Long term stability:
No mechanical component design, far exceeding the lifespan of traditional relays

Product Selection

Control Voltage Output Voltage Rated operational current            
    15Amps 25Amps 40Amps 60Amps 80Amps 100Amps 120Amps
3 - 32VDC 280VAC"Z" VSR815DA28Z VSR825DA28Z VSR840DA28Z VSR860DA28Z VSR880DA28Z VSR8100DA28Z VSR8120DA28Z
3 - 32VDC 280VAC"R" VSR815DA28R VSR825DA28R VSR840DA28R VSR860DA28R VSR880DA28R VSR8100DA28R VSR8120DA28R
90 - 280VAC 280VAC"Z" VSR815AA28Z VSR825AA28Z VSR840AA28Z VSR860AA28Z VSR880AA28Z VSR8100AA28Z VSR8120AA28Z
90 - 280VAC 280VAC"R" VSR815AA28R VSR825AA28R VSR840AA28R VSR860AA28R VSR880AA28R VSR8100AA28R VSR8120AA28R
3 - 32VDC 480VAC"Z" VSR815DA48Z VSR825DA48Z VSR840DA48Z VSR860DA48Z VSR880DA48Z VSR8100DA48Z VSR8120DA48Z
3 - 32VDC 480VAC"R" VSR815DA48R VSR825DA48R VSR840DA48R VSR860DA48R VSR880DA48R VSR8100DA48R VSR8120DA48R
90 - 280VAC 480VAC"Z" VSR815AA48Z VSR825AA48Z VSR840AA48Z VSR860AA48Z VSR880AA48Z VSR8100AA48Z VSR8120AA48Z
90 - 280VAC 480VAC"R" VSR815AA48R VSR825AA48R VSR840AA48R VSR860AA48R VSR880AA48R VSR8100AA48R VSR8120AA48R
3 - 32VDC 660VAC"Z" VSR815DA66Z VSR825DA66Z VSR840DA66Z VSR860DA66Z VSR880DA66Z VSR8100DA66Z VSR8120DA66Z
3 - 32VDC 660VAC"R" VSR815DA66R VSR825DA66R VSR840DA66R VSR860DA66R VSR880DA66R VSR8100DA66R VSR8120DA66R
90 - 280VAC 660VAC"Z" VSR815AA66Z VSR825AA66Z VSR840AA66Z VSR860AA66Z VSR880AA66Z VSR8100AA66Z VSR8120AA66Z
90 - 280VAC 660VAC"R" VSR815AA66R VSR825AA66R VSR840AA66R VSR860AA66R VSR880AA66R VSR8100AA66R VSR8120AA66R
Description 15A 25A 40A 60A 80A 100A 120A
Dielectric Strength, Input to Output [50/60 Hz] 4000Vrms
Dielectric Strength, Input/Output to Base [50/60 Hz] 2500Vrms
Minimum Insulation Resistance [@ 500 VDC] 10⁹Ω
Maximum Capacitance, Input/Output 0.8pF
Ambient Operating Temperature Range -30to80℃
Ambient Storage Temperature Range -30to100℃
Input Terminal Screw Torque Range [in-Ib/Nm] 11-18/1.2-2.0
Load Terminal Screw Torque Range [in-Ib/Nm] 18-26/2-3
SSR Mounting Screw Torque Range [in-Ib/Nm] 11-16/1.2-1.8
Humidity per IEC60068-2-78 95%
LED Input Status Indicator Red
Housing Material PBT+30%GF
Baseplate Material Purecopper
Weight 145g
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.