Key attributes

Brand MV Switchgear Accessories
Model NO. VSC Series Single Phase Solid State Relays
额定工作电流 25Amps
Series VSC

Product descriptions from the supplier

Description

Solid state relay (SSR) is a contactless switching device implemented using microelectronics and power electronics technology. It abandons the mechanical contacts of traditional electromagnetic relays and uses semiconductor devices to complete on-off control. The VSC series single-phase solid-state relay is a high-performance product based on this technology, which is worth considering in situations where reliable, efficient, and long-life switch control is required

dvantages of VSC series single-phase solid-state relay products:
The VSC series single-phase solid-state relays integrate the core advantages of modern solid-state switching technology: long lifespan (no contact wear), high reliability (no sparks, vibration resistance), silent operation (no action noise), fast response (microsecond level switching speed), and excellent anti-interference ability. Its compact design facilitates installation and integration, and is well compatible with common logic level signals such as TTL, DTL, HTL, requiring only a small control signal to drive high current loads.

VSC series single-phase solid-state relay product features:
1. Wide range current and voltage adaptation:
We offer three rated current specifications of 10A, 15A, and 25A, with a working voltage range of 24-280VAC, to meet the power requirements of various single-phase loads.
2. Flexible conduction mode:
Supports two output modes: Zero Crossing or Random Turn On. Zero voltage conduction effectively reduces surge current and protects sensitive loads (such as incandescent lamps and heaters); The instantaneous derivative principle is applicable to control scenarios that require rapid response.
3. Convenient installation and connection:
The design emphasizes user friendliness, with clear and intuitive wiring terminals, a simple and efficient installation process, and effectively shortens project time
4. Clear status indication:
Built in LED input status indicator light, visually displaying the on/off status of control signals, facilitating on-site installation, debugging, and operation status monitoring.
5. Inherent advantages of solid-state technology:
No mechanical contacts, completely eliminating arcs, sparks, and mechanical wear; The switch action is quiet and silent, with strong resistance to electromagnetic interference (EMI) and shock and vibration, suitable for harsh industrial environments.

Product Selection

Control voltage Dutput voltage Rated operational current
10Amps 15Amps 25Amps
4-8VDC 280VAC”Z” VSC10D05AZ VSC15D05AZ VSC25D05AZ
4-8VDC 280VAC”R” VSC10D05AR VSC15D05AR VSC25D05AR
10-14VDC 280VAC”Z” VSC10D12AZ VSC15D12AZ VSC25D12AZ
10-14VDC 280VAC”R” VSC10D12AR VSC15D12AR VSC25D12AR
21-27VDC 280VAC”Z” VSC10D24AZ VSC15D24AZ VSC25D24AZ
21-27VDC 280VAC”R” VSC10D24AR VSC15D24AR VSC25D24AR

Input Specifications

Must Turn-Off Voltage   1VDC 1VDC 1VDC
Minimum Turn-On Voltage   4VDC 10DC 21VDC
Minimum Input Current   6mA 10mA 8mA
Maximum Turn-On Time [msec]   1/2Cycle 1/2Cycle 1/2Cycle
Maximum Turn-Off Time [msec]  1/2Cycle 1/2Cycle 1/2Cycle
Maximum Input Current   21mA 17.5mA 19mA
Description   D05 D12 D24
Control Voltage Range   4-8VDC 10-14VDC 21-27VDC

Output Specifications

Description 10Amps 15Amps 25Amps
Maximum l?t for fusing
[50/60Hz,1/2Cycle][A?sce]
100/95 165/160 338/326
Maximum load current [Adc] 10A 15A 25A
Maximum off-state leakage current
@rated voltage[mArms]
0.1 0.1 0.1
Maximum on-state voltage drop
@rated current [Volts]
1.3 1.3 1.3
Maximum surge current
[50/60Hz,1Cycle][Apk]
145/150 185/220 260/280
Minimum load current [mArms] 150 150 250
Minimum off-state dv/dt
aMaximum rated voltage [V/μsec
500 500 500
Minimum power factor
[at maximum  load]
0.7 0.7 0.7
Operating voltage [47-63Hz][Vrms] 24-280 24-280 24-280
Thermal resistance junction to case
[Rjc][°C/W]
3.0 2.2 0.9
Transient overvoltage [Vpk] 600 600 600
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.