• Suspension clamp poles in straight lines and angles
Suspension clamp poles in straight lines and angles
discuss personally
Model
SO99-18
Basic info
Brand Wone Store
Model NO. Suspension clamp poles in straight lines and angles
Rated frequency 50/60Hz
Series SO
Product Detail

Product Introduction

The Suspension Clamp for Straight & Angle Poles is a specialized hardware component for overhead power transmission/distribution lines. It is engineered to mount on straight-line poles (used in linear sections of power lines) and angle poles (installed at line turning points), serving to suspend, secure, and stabilize conductors (wires/ground wires). By bearing the weight of conductors and balancing horizontal/vertical forces (especially critical for angle poles), it maintains safe line spacing, prevents conductor sag or displacement, and ensures reliable power transmission—widely applied in 10kV–500kV overhead grids for residential, industrial, and rural electrification.

Features

  • Dual Compatibility: Straight & Angle Poles:Designed to fit both straight-line poles (for linear line segments) and angle poles (for line turns, 30°–90° typical), eliminating the need for separate clamps for different pole types. Optimized mounting structures adapt to pole diameters (150mm–300mm common) and surface shapes.

  • Secure Conductor Fixing & Force Balance:Features a grooved or rubber-lined inner design to grip conductors tightly without damaging insulation. For angle poles, it resists horizontal pull from conductor tension at turns, preventing conductor slippage and maintaining line alignment—critical for avoiding short circuits from line contact.

  • High Load-Bearing Capacity:Constructed from high-strength materials (e.g., aluminum alloy, hot-dip galvanized steel), it supports conductor weights (up to 500kg depending on model) and withstands dynamic loads from wind, ice, or temperature changes. Ensures long-term stability without deformation.

  • Weather & Corrosion Resistance:Surface treatments (hot-dip galvanizing, anti-UV coating) protect against outdoor elements: rain, humidity, salt spray (for coastal areas), and UV radiation. Prevents rust or material degradation, extending service life to 15–20 years in harsh environments.

  • Easy Installation & Maintenance:Modular design with simple fastening parts (bolts, washers) allows quick on-site installation—no specialized tools required. Smooth surface and detachable components simplify inspections or conductor adjustments, reducing maintenance time and labor costs.

  • Compliance with Industry Standards:Meets international standards (e.g., IEC 61284, ANSI C119.4) and local grid regulations, ensuring compatibility with global overhead line systems. Rigorous testing (load, corrosion, temperature cycling) guarantees performance in real-world power transmission scenarios.

Main Parameters

Certificates

Standards

EN 50483-2:2009

Dimensions

Weight

0.843 kg

Height

162 mm

Width

70 mm

Length

140 mm

Conductor size

4x25 ... 4x95 mm²

Conductor diameter

18 ... 39 mm

Electrical values

Test voltage

4 kV / 50 Hz / 1 min

Mechanical

SMFL

18 kN

Tightening torque Nm

12 Nm

ETIM

ETIM Class

EC003516

Type of accessory/spare part

Other

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!