Solar Power Equipment Box-type Transformer(Prefabricated Substation)

  • Solar Power Equipment Box-type Transformer(Prefabricated Substation)

Key attributes

Brand Vziman
Model NO. Solar Power Equipment Box-type Transformer
Rated voltage 33kV
Capacity 500kVA-1600kVA
Series Compact Substation

Product descriptions from the supplier

Description

Product overview: 

  • A Solar Power Equipment Box-type Transformer that integrates 0.27kV 0.315kV 0.69kv voltage of grid-connected photovoltaic inverter into power grid output energy through a boost transformer.

  •  High-voltage switchgear, transformer body and protective fuse are centrally placed in the oil tank. High-voltage/low-voltage pre-installed substation is set up together with low-voltage switchgear and corresponding auxiliary equipment.

  •  Mainly used for small and medium-sized solar power generation.

  •  Execution standard: IEC61850 series, GB/T17467, etc.

Product advantages:

Leading technology:

  •  Standard anti-corrosion and salt spray environmental plan to meet the stringent environmental requirements of the site.

  •  Compact structure, small footprint, easy installation.

  •  Fully enclosed, fully insulated structure, safe and reliable operation.

  •  Easy to operate, maintenance-free, low equipment cost.

Enclosure:

  •  Adopt cold rolled high quality hot dip galvanized sheet.

  •  The surface is treated by electrostatic spray, and the paint can not be taken off for 50 years.

  •  Laser numerical control equipment cutting, drilling, bending, to ensure the processing accuracy.

  •  Product structure is divided into three parts: high voltage chamber, low voltage chamber and transformer.

  •  The cabinet is mainly pre-installed with: lightning arrester, load switch, transformer tap switch, protection fuse, oil level thermometer, oil level gauge, pressure relief valve, amount of oil discharge valve and other accessories.

  •  The low-voltage side is equipped with main circuit breaker, overvoltage protector, and can be designed and installed in complete sets of automatic measurement and intelligent control system.

  •  The transformer is a low loss oil-immersed transformer produced by WONE You Electric.

Functional units:

  •  Fully sealed structure, using the transformer insulating oil as the insulating medium and heat dissipation medium, overall has the advantages of compact structure, good heat dissipation performance.

  •  The high-voltage indoor door should be equipped with electromagnetic lock and live display. When the high-voltage side is live, the high-voltage chamber door cannot be opened.

  • The external door of the box transformer should be equipped with mechanical lock to meet the five requirements of high-pressure products and ensure personal safety.

 Components:

  •  Choose high-quality brand components such as Chint, Shanghai People Electric, Changshu Electric, etc.

  •  Schneider, ABB high-quality partners.

Supplementary material:

  •  High quality tin - plated busbar copper bar, with insulation sleeve.

  •  Hanhe cable is selected for secondary wiring.

 Processing and assembly:

  • Assembly workers have been trained for at least 6 months.

  • Secondary wiring is fully automatic equipment cutting to ensure reliable wiring.

  • Use power tools to ensure proper torque for bolting reinforcement.

  • The copper wire bus is NC punched and bent.

  • All kinds of experimental tests before leaving the factory to ensure normal operation.

Product parameters:

  • Voltage:0.69kV/33kV  0.69kV/11kV.

Conditions of use:

  •  Altitude: ≦2000m.

  • Ambient temperature range: -45℃ -- +45℃.

  • Outdoor wind speed: ≤35m/s.

  • Relative humidity: daily mean ≤95%, monthly mean ≤90%.

  • Installation location: Install in the place without fire, explosion risk, serious pollution, chemical corrosion and violent vibration.

  • If the above normal operating conditions are exceeded, customers can contact our company for customized solutions.

  • The above is suitable for 50/60Hz photovoltaic power generation system, the rated capacity of the transformer is 500~ 1600kVA.

Ordering instructions:

When ordering, the customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  •  Equipment layout drawing, combination drawing, floor plan drawing.

  • Brand, model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Device surface color.

  • Other special requirements can be negotiated with the manufacturer.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    1. Challenges in High-Voltage Power Systems1.1 High-voltage power systems, as the core of power transmission, face critical challenges: Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements. Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages. Poor Environmental Adapt
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 Grid Frequency Fluctuations and Stability IssuesThe intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within mil
    05/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.