Single Phase Compact Oil Immersed Power Distribution Transformer

  • Single Phase Compact Oil Immersed Power Distribution Transformer

Key attributes

Brand ROCKWILL
Model NO. Single Phase Compact Oil Immersed Power Distribution Transformer
Rated voltage 11kV
Rated frequency 50/60Hz
Rated capacity 125kVA
Series D

Product descriptions from the supplier

Description

Product Overview

Rockwill's Single Phase Distribution Transformers combine proven engineering with innovative design to deliver unmatched reliability for residential, commercial and industrial applications. Our transformers feature optimized construction and premium materials to ensure superior performance in diverse operating conditions.

Key Features & Benefits

  • Optimized Thermal Design: 15% better cooling efficiency than conventional models

  • Short-Circuit Reinforced: Withstands 25x rated current for 2 seconds

  • Low Noise Operation: <45dB for urban installations

  • Eco-Friendly Options: Biodegradable ester oil available

  • Smart Monitoring Ready:Optional IoT connectivity for predictive maintenance

Technical Specifications

  • Capacity Range: 10kVA to 333kVA

  • Primary Voltage: Up to 34.5kV

  • Standards Compliance: IEEE C.57, IEC 60076, ANSI/CSA

  • Temperature Range: -25&deg;C to +40&deg;C (standard) / Custom designs available

Product Parameters

Reliable Engineering Design

  • Advanced Spiral Coil Designwith longitudinal oil channels for enhanced heat dissipation

  • Reinforced Coil Support Systemfor superior short-circuit current resistance

  • Patented Lifting Structureensures safe transportation and installation

  • Rigorous Quality Controlwith multiple structural improvements based on decades of field experience

Premium Material Selection

  • Oxygen-Free Copper Windingswith special surface treatment for reduced load loss

  • High-Grade Silicon Steel Coreswith ultra-low unit loss for minimized no-load consumption

  • Industrial-Grade Laminated Wood Insulationmaintains structural integrity under short-circuit conditions

  • Deep-Filtered Transformer Oilwith minimal moisture/gas content for stable operation

  • Aging-Resistant Sealsprevent leaks throughout the service life

  • ISO 9000 Certified Materialsfrom rigorously audited suppliers

Application Scenarios

  • Urban Power Distribution: Compact designs for space-constrained installations

  • Rural Electrification: Robust construction for harsh environments

  • Commercial Complexes: Low-noise operation for sensitive areas

  • Industrial Parks: High overload capacity for variable loads

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Risk Identification and Control Measures for Distribution Transformer Replacement Work
    1.Electric Shock Risk Prevention and ControlAccording to typical design standards for distribution network upgrades, the distance between the transformer’s drop-out fuse and the high-voltage terminal is 1.5 meters. If a crane is used for replacement, it is often impossible to maintain the required minimum safety clearance of 2 meters between the crane boom, lifting gear, slings, wire ropes, and the 10 kV live parts, posing a severe risk of electric shock.Control Measures:Measure 1:De-energize th
    12/25/2025
  • Analysis of Common Faults and Causes in Routine Inspection of Distribution Transformers
    Common Faults and Causes in Routine Inspection of Distribution TransformersAs the terminal component of power transmission and distribution systems, distribution transformers play a critical role in supplying reliable electricity to end users. However, many users have limited knowledge of power equipment, and routine maintenance is often carried out without professional support. If any of the following conditions are observed during transformer operation, immediate action should be taken: Excess
    12/24/2025
  • Analysis of Lightning Protection Measures for Distribution Transformers
    Analysis of Lightning Protection Measures for Distribution TransformersTo prevent lightning surge intrusion and ensure the safe operation of distribution transformers, this paper presents applicable lightning protection measures that can effectively enhance their lightning withstand capability.1. Lightning Protection Measures for Distribution Transformers1.1 Install surge arresters on the high-voltage (HV) side of the distribution transformer.According to SDJ7–79 Technical Code for Overvol
    12/24/2025

Related Solutions

  • Innovative Application Solutions for Single-Phase Distribution Transformers in U.S. Rural and Suburban Grid Modernization
    1 Rural Grid Challenges and Technical Advantages of Single-Phase TransformersThe U.S. rural and suburban grid faces critical challenges: aging infrastructure and low load density result in inefficient power supply, with line losses reaching 7%&ndash;12%&mdash;significantly higher than urban grids (4%&ndash;6%). Over 60% of rural areas exceed the 300-meter power supply radius standard, causing widespread voltage instability (peak voltage drops of 15%&ndash;20%). Three-phase transf
    06/19/2025
  • Single-Phase Distribution Transformers: The Key to Flexible and Efficient Deployment of EV Charging Infrastructure
    Single-Phase Distribution Transformers: The Key to Flexible and Efficient Deployment of EV Charging InfrastructureAmid the rapid deployment of EV charging infrastructure, overcoming grid limitations and achieving cost-effective flexible layouts has become critical. Traditional three-phase power supply solutions often face challenges like lengthy installation cycles and extensive modifications, particularly struggling in imbalanced distributed scenarios. Single-phase distribution transformers are
    06/19/2025
  • Advanced Solutions for Single Phase Distribution Transformers in the US Market
    Ⅰ. Characteristics of the U.S. Power System & Technical Requirements for Single-Phase TransformersThe U.S. power system utilizes a 480V/277V three-phase four-wire system as the primary power supply standard for commercial facilities, while residential applications adopt a 120V/240V single-phase three-wire system.Technical Parameters: Input Voltage: Must cover a fluctuation range of &plusmn;10% (e.g., 277V &plusmn;27.7V). Output Voltage Accuracy: Controlled within &plusmn;3%. Insu
    06/19/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.