• SF6-free gas-insulated switchgear for primary distribution
SF6-free gas-insulated switchgear for primary distribution
discuss personally
Model
ZX2-24
ZX2-17.5
ZX2-12
Basic info
Brand ABB
Model NO. SF6-free gas-insulated switchgear for primary distribution
Rated voltage 17.5kV
Rated frequency 50/60Hz
Series PrimeGear ZX2
Product Detail

Customer benefits:

Compliant with IEC standards and F-gas regulation

  •  Compliant with IEC standards and with the EU F-gas regulation (EU) 2024/573.

  •  High ratings up to 2500A. Single busbar modular and compact lowpressure design, based on natural origin gases (SF6 free).

  •  Loss of service continuity LSC 2A  and partition class PM*.

Reliable and flexible 

  • Compact and modular design for space optimization. 

  • Very low maintenance required as all high voltage parts are permanently sealed in a gas tank and protected from soiling, humidity, foreign bodies, and other environmental influences.

  • Due to the low-pressure design,  the switchgear can remain in service  up to the point of repair, even in the unlikely event of a leak. 

  • The switchgear can be enabled with monitoring and diagnostics (e.g., temperature, gas, partial discharge)  to track asset health. Automation and control features based on current and voltage sensors and IEC 61850 protocol allow for customization during the manufacturing phase and varying loads during operations.

  • Well known and proven vacuum circuit breaker type VD4X. 

  • Outer cone cable termination system.

Safety 

  •  High level of operator safety with front, lateral and rear arc protection,  certified AFL(R) 40kA 1s (according to IEC 62271-200). 

  • Plug-in busbar technology and the factory-assembled pressure relief duct allows for safe, quick and easy installation at site. 

  • With the switchgear diagram and operation controls on the front panel, no opening of the doors  is required for manual operation making the switchgear operator friendly.

  •  Wide range of monitoring and diagnostic features for safe and reliable operations. All switching devices are motor-operated and  can be controlled remotely.

  •  Mechanical and electrical interlocks prevent incorrect operation of the switchgear panels.

Technical parameters:

Structure diagram:

 

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
SF6-free gas-insulated switchgear for primary distribution
Manual English
PDF
FAQ
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A:
Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A:
Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Q: What are the maintenance requirements associated with the air-insulated switchgear (AIS) vs gas-insulated (GIS)?
A:
Gas-insulated switchgear requires very low maintenance as all high voltage parts are permanently protected in a gas tank from soiling, humidity, entry of foreign bodies and other environmental influences. Primary, the drives located outside gas compartment require inspection and maintenance. On the other hand, gas-insulated switchgear repair requires additional training (e.g. for gas works) and the replacement or parts may not be as easily. In the air-insulated switchgear visual inspection is recommended in regular intervals, maintenance of power parts is given in installation, operation and maintenance manual (1VLM000363).
Q: What smart solutions are available for ABB’s AIS portfolio?
A:
ABB’s switchgear smart solutions are designed to help our customers make data-driven decisions. Our customers can benefit from a wide range monitoring, diagnostic, automation and control features for their ABB’s air-insulated medium voltage switchgear. Contact our sales team to learn more about ABB’s smart solutions for each of our switchgear.
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!