China SF6-free Dead Tank Circuit Breaker Manufacturer-72.5 kV

  • China SF6-free Dead Tank Circuit Breaker Manufacturer-72.5 kV

Key attributes

Brand ROCKWILL
Series RVD
Rated voltage 72.5kV
Rated frequency 60 Hz
At lightning impulse 350kV
Rated normal current 1200/2000/3000 A
Rated short-circuit making current 100 kA
Description

Rockwill Group is a leading high-tech enterprise in China, specializing in the R&D, manufacturing, and sales of medium- and high-voltage switchgear and components for over 20 years. Following Pinggao Electric, XD Group, and XJ Electric, Rockwill Group is one of the few domestic manufacturers in China that has independently mastered the core technology of 72.5kV SF₆-free dead tank circuit breakers and successfully commercialized the product.

Based on this expertise, we have developed an SF₆-free dead tank circuit breaker (DTCB) that is very similar to its SF₆ predecessor. Using our g³ insulating and switching SF₆-free technology, the new RVD-72.5 remains compact with the same footprint. Performance and life cycle costs remain similar while offering a significant decrease in the carbon footprint.

The SF₆-free gas mixture used in the new RVD-72.5 works on the same well-known principle for insulation and breaking purposes as that of SF₆ gas. The g³ gas is a mixture of carbon dioxide (CO₂) with oxygen (O₂) and a small percentage of an additive (C4F7N), whose physical properties are essential to g³. Its contribution to global warming is significantly lower than that of SF₆ gas – reduced by 99%.

Product Showcase Video

Main Characteristics

Advanced self-blast interrupters

  • Shares many components with the RHD-72.5 SF₆ circuit breaker
  • Durable low-energy spring-spring operated mechanisms
  • 2 μs chopped wave 452 kV
  • Zero bar withstand capability

 Easy System Integration

  • Breakers are completely factory assembled, wired and tested before shipment
  • Similar operational and maintenance procedures as with SF₆ circuit breakers
  • Compact design that’s common to all substation applications, including extension of existing substations

Technical specifications

IEC VALUE UNITS
Rated voltage 72.5 kV
Rated frequency 60 Hz

Rated insulation level   

  • at power frequency, dry
  • at power frequency, wet
160 kV
140 kV
At lightning impulse 350 kV
Rated normal current 1200/2000/3000 A
Rated short-circuit breaking current 40 kA
Rated short-circuit making current     100 kA
Rated break time 50 ms
Rated operating sequence O-CO-15s-CO
O-0.3s-CO-180s-CO

Dimensions

SF₆-free Dead Tank Circuit Breaker Dimensions

Environmental Conditions

Ambient air temperature upper limit +40 °C
Ambient air temperature 24-hour average +35 °C
Ambient air temperature lower limit –30 °C
Altitude above sea level ≤ 1000 m
Relative humidity (24-hour average) ≤ 95%
Relative humidity (monthly average) ≤ 90%
Water vapor pressure (24-hour average) ≤ 2.2 kPa
Water vapor pressure (monthly average) ≤ 1.8 kPa
Solar radiation ≤ 1000 W/m²
Pollution level Level III
Seismic capability High seismic per IEEE 693

Application Scenarios

  • Urban & Industrial 72.5 kV Distribution Substations
  • Renewable Energy Step-Up / Grid Integration
  • Existing Substation Retrofit & Extension
  • High-Seismic Regions
  • Green / Eco-Sensitive Grid Projects

Solutions - SF₆-free Dead Tank Circuit Breaker

  • South Africa Regional Dead Tank SF6 Circuit Breaker Solution Report
    Ⅰ. Project BackgroundAs the first African country adopting dead tank SF₆ circuit breaker technology, South Africa's grid system faces these challenges: Aging Dead Tank SF₆ Circuit Breakers:Existing high-voltage circuit breakers exhibit severe aging, particularly legacy dead tank SF₆ circuit breakers with increased failure rates. Dead Tank SF₆ Circuit Breaker Limitations:In high-altitude regions (>2,000m), conventional dead tank SF₆ circuit breakers experience insulation degradation from low-t
  • Dead Tank SF6 Circuit Breaker Solution for African Plateau Regions (Ethiopia)
    Project BackgroundEthiopia, located in the East African plateau, has an average altitude exceeding 3,000 meters. In some areas, winter temperatures can drop to -30°C, accompanied by significant diurnal temperature variations (up to 25°C daily) and intense ultraviolet radiation. The local power system faces the following challenges: SF₆ Gas Liquefaction Risk:Traditional Dead Tank SF₆ Circuit Breakers are prone to SF₆ gas liquefaction at low temperatures (critical liquefaction temperature ≈ -28.5°

Documentation Resource Library SF₆-free Dead Tank Circuit Breaker

RVD-145 Dead tank vacuum circuit breaker
Restricted
RVD-145 Dead tank vacuum circuit breaker RVD-145 Dead tank vacuum circuit breaker
Catalogue
English
PDF
RVD-145  Dead tank vacuum circuit breaker
Public
RVD-145 Dead tank vacuum circuit breaker RVD-145 Dead tank vacuum circuit breaker
Brochure
English
RVD Dead tank SF6 Free/vacuum circuit breaker
Public
RVD Dead tank SF6 Free/vacuum circuit breaker RVD Dead tank SF6 Free/vacuum circuit breaker
Brochure
English
Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

Yes. It keeps the same compact footprint as its SF₆ predecessor. Maintenance and operation procedures are similar, easy for substation retrofit and extension.

Rockwill is one of the few Chinese manufacturers that independently mastered and commercialized 72.5kV SF₆-free dead tank breaker core technology, with over 20 years of MV & HV switchgear R&D and production experience.

It is equipped with advanced self-blast interrupters and durable low-energy spring-spring operating mechanisms. Many parts are interchangeable with RHD-72.5 SF₆ circuit breaker.

The breaker is fully assembled, wired and tested in factory before shipment to simplify on-site installation and commissioning.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?