100kV 126kV 138kV 145kV High-voltage AC Dead tank SF6 circuit breaker

  • 100kV 126kV 138kV 145kV High-voltage AC Dead tank SF6 circuit breaker

Key attributes

Brand ROCKWILL
Series RHD
Rated maximum voltage 145kV/170kV
Rated maximum current 2000-4000A
Rated short-circuit breaking current 31.5-50kA
Rated frequency 50/60Hz
Description

Description

We are the pioneer in China's GIS tank circuit breaker industry and the country's first source factory specializing exclusively in this field.Outdoor 126kV High-voltage AC  Dead tank SF6 circuit breaker is an outdoor - installed, three - pole, 50Hz AC high - voltage switching device that uses SF6 gas as the arc - extinguishing and insulating medium. It can be used to interrupt and close rated current and fault current, interrupt and close capacitor banks, transfer circuits, and also be used as a tie - circuit breaker to achieve the control and protection of power transmission and transformation lines and equipment. It is especially suitable for frequent operations. The circuit breaker is equipped with a spring operating mechanism.

Main Features

The material of the contact end is copper - tungsten alloy, which has strong arc - resistance ability. Especially during the opening and closing process of the circuit breaker, an arc will be generated, and a large amount of energy acts on the arcing contacts. Therefore, the ablation - resistant material is an important guarantee for the electrical life. The large and small nozzles are made of polytetrafluoroethylene material with excellent high - temperature and arc - resistance properties and appropriate fillers.

Technical specifications

Among these, some SF6 tank circuit breakers cover non-standard voltage levels including 100kV 123kV 126kV 138kV 145kV 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV, 756kV, and 800kV with a rated short-circuit breaking current of 50kA or 63kA, and we offer customization services.

Rated Voltage

kV

123kV 126kV 138kV 145kV

Rated Current

A

3150A 4000A

Rated Frequency

Hz

50/60

First - Pole - To - Clear Factor

/

1.5

Rated Short - circuit Breaking Current

kA

40

Rated Short - time Withstand Current (Effective Value)

kA/s

40/4

Rated Peak Withstand Current

kA

100

Rated Power - frequency Withstand Voltage

Phase - to - phase/Ground

kV

230

Break - port

230(+73)

Rated Lightning Impulse Withstand Voltage (1/250μs Peak Value)

Phase - to - phase/Ground

550

Break - port

550(+103)

SF₆ Gas (Gauge Pressure, 20℃)

Rated Gas Pressure

Mpa

0.60

Alarm Gas Pressure

0.55±0.015

Lock - out Gas Pressure

0.50±0.015

Rated Operating Sequence

/

O - 0.3s - CO - 180s - CO

Rated Out - of - step Breaking Current

kA

10

Short - line Fault Breaking Current

kA

L90:36, L70:28

Asymmetrical - Phase Ground Fault Breaking Current

kA

34.8

Rated Line Charging Breaking Current

A

31.5

Rated Cable Charging Breaking Current

A

140

Number of Breaking Operations for Rated Short - circuit Breaking Current

times

20

Mechanical Life

times

10000

Mechanism/Operation Mode

/

Spring Operating Mechanism/Three - phase Mechanical Interlock

 

Solutions - Dead Tank Circuit Breaker

  • Dead Tank SF6 Circuit Breaker Solution for African Plateau Regions (Ethiopia)
    Project BackgroundEthiopia, located in the East African plateau, has an average altitude exceeding 3,000 meters. In some areas, winter temperatures can drop to -30°C, accompanied by significant diurnal temperature variations (up to 25°C daily) and intense ultraviolet radiation. The local power system faces the following challenges: SF₆ Gas Liquefaction Risk:Traditional Dead Tank SF₆ Circuit Breakers are prone to SF₆ gas liquefaction at low temperatures (critical liquefaction temperature ≈ -28.5°

Documentation Resource Library Dead Tank Circuit Breaker

Restricted
Dead Tank Circuit Breakers Catalog Dead Tank Circuit Breakers Catalog
Catalogue
English
PDF
Restricted
RHD-126/145 Dead Tank Circuit-Breaker RHD-126/145 Dead Tank Circuit-Breaker
Drawings
English
PDF
Public.
RHD-145 SF6 Gas Dead tank Circuit Breaker FLYER RHD-145 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Restricted
2026 RHD Dead tank SF6 gas circuit breaker 2026 RHD Dead tank SF6 gas circuit breaker
Catalogue
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Public.
RHD-72.5 SF6 Gas Dead tank Circuit Breaker FLYER RHD-72.5 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-170 SF6 Gas Dead tank Circuit Breaker FLYER RHD-170 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-245 SF6 Gas Dead tank Circuit Breaker FLYER RHD-245 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-145 SF6 Gas Dead tank Circuit Breaker RHD-145 SF6 Gas Dead tank Circuit Breaker
Drawings
English
Public.
RHD-170 SF6 Gas Dead tank Circuit Breaker RHD-170 SF6 Gas Dead tank Circuit Breaker
Drawings
English

Frequently asked questions

The interrupter is typically installed inside the tank, resulting in a highly compact overall structure that enables efficient arc quenching within a limited space. Depending on the arc extinguishing principle and technical approach, the specific configuration of the interrupter may vary, but all designs include core components such as moving/stationary contacts, a nozzle, and insulating parts. During opening operation to interrupt the current, these components work together to achieve fast and reliable extinction of the arc.

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register