  • 100kV 126kV 138kV 145kV High-voltage AC Dead tank SF6 circuit breaker

السمات الرئيسية

العلامة التجارية ROCKWILL
سلسلة RHD
الوصف

Description

We are the pioneer in China's GIS tank circuit breaker industry and the country's first source factory specializing exclusively in this field.Outdoor 126kV High-voltage AC  Dead tank SF6 circuit breaker is an outdoor - installed, three - pole, 50Hz AC high - voltage switching device that uses SF6 gas as the arc - extinguishing and insulating medium. It can be used to interrupt and close rated current and fault current, interrupt and close capacitor banks, transfer circuits, and also be used as a tie - circuit breaker to achieve the control and protection of power transmission and transformation lines and equipment. It is especially suitable for frequent operations. The circuit breaker is equipped with a spring operating mechanism.

Main Features

The material of the contact end is copper - tungsten alloy, which has strong arc - resistance ability. Especially during the opening and closing process of the circuit breaker, an arc will be generated, and a large amount of energy acts on the arcing contacts. Therefore, the ablation - resistant material is an important guarantee for the electrical life. The large and small nozzles are made of polytetrafluoroethylene material with excellent high - temperature and arc - resistance properties and appropriate fillers.

Technical specifications

Among these, some SF6 tank circuit breakers cover non-standard voltage levels including 100kV 123kV 126kV 138kV 145kV 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV, 756kV, and 800kV with a rated short-circuit breaking current of 50kA or 63kA, and we offer customization services.

Rated Voltage

kV

123kV 126kV 138kV 145kV

Rated Current

A

3150A 4000A

Rated Frequency

Hz

50/60

First - Pole - To - Clear Factor

/

1.5

Rated Short - circuit Breaking Current

kA

40

Rated Short - time Withstand Current (Effective Value)

kA/s

40/4

Rated Peak Withstand Current

kA

100

Rated Power - frequency Withstand Voltage

Phase - to - phase/Ground

kV

230

Break - port

230(+73)

Rated Lightning Impulse Withstand Voltage (1/250μs Peak Value)

Phase - to - phase/Ground

550

Break - port

550(+103)

SF₆ Gas (Gauge Pressure, 20℃)

Rated Gas Pressure

Mpa

0.60

Alarm Gas Pressure

0.55±0.015

Lock - out Gas Pressure

0.50±0.015

Rated Operating Sequence

/

O - 0.3s - CO - 180s - CO

Rated Out - of - step Breaking Current

kA

10

Short - line Fault Breaking Current

kA

L90:36, L70:28

Asymmetrical - Phase Ground Fault Breaking Current

kA

34.8

Rated Line Charging Breaking Current

A

31.5

Rated Cable Charging Breaking Current

A

140

Number of Breaking Operations for Rated Short - circuit Breaking Current

times

20

Mechanical Life

times

10000

Mechanism/Operation Mode

/

Spring Operating Mechanism/Three - phase Mechanical Interlock

 

حلول - Dead Tank Circuit Breaker

  • حل لكسر دائرة الغاز السفلي لـ IEE-Business للمناطق المرتفعة في أفريقيا (إثيوبيا)
    خلفية المشروع​توجد إثيوبيا على المرتفعات الأفريقية الشرقية، بمتوسط ارتفاع يتجاوز 3,000 متر. في بعض المناطق، يمكن أن تنخفض درجات الحرارة الشتوية إلى -30°C، مع تغيرات حرارية يومية كبيرة (تصل إلى 25°C يومياً) وأشعة فوق بنفسجية شديدة. يواجه النظام الكهربائي المحلي التحديات التالية:​مخاطر تسييل غاز SF6: تكون المفاتيح القاطعة التقليدية لخزان الموت من نوع SF6 عرضة للتسييل عند درجات الحرارة المنخفضة (درجة الحرارة الحرجة للتسييل ≈ -28.5°C)، مما يؤثر على أداء العزل والقضاء على الشرارة، و

مكتبة موارد الوثائق Dead Tank Circuit Breaker

Restricted
Dead Tank Circuit Breakers Catalog Dead Tank Circuit Breakers Catalog
Catalogue
English
PDF
Restricted
RHD-126/145 Dead Tank Circuit-Breaker RHD-126/145 Dead Tank Circuit-Breaker
Drawings
English
PDF
Public.
RHD-145 SF6 Gas Dead tank Circuit Breaker FLYER RHD-145 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Restricted
2026 RHD Dead tank SF6 gas circuit breaker 2026 RHD Dead tank SF6 gas circuit breaker
Catalogue
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Public.
RHD-72.5 SF6 Gas Dead tank Circuit Breaker FLYER RHD-72.5 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-170 SF6 Gas Dead tank Circuit Breaker FLYER RHD-170 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-245 SF6 Gas Dead tank Circuit Breaker FLYER RHD-245 SF6 Gas Dead tank Circuit Breaker FLYER
Brochure
English
Public.
RHD-145 SF6 Gas Dead tank Circuit Breaker RHD-145 SF6 Gas Dead tank Circuit Breaker
Drawings
English
Public.
RHD-170 SF6 Gas Dead tank Circuit Breaker RHD-170 SF6 Gas Dead tank Circuit Breaker
Drawings
English

الأسئلة الشائعة

الهيكل المتكامل للخزان:

  • الهيكل المتكامل للخزان: يتم تغليف غرفة إخماد القوس الكهربائي، والوسط العازل، والمكونات ذات الصلة داخل خزان معدني مملوء بغاز عازل (مثل سداسي فلوريد الكبريت) أو زيت عازل. هذا يشكل مساحة مستقلة نسبيًا ومغلقة بشكل فعال، مما يمنع العوامل البيئية الخارجية من التأثير على المكونات الداخلية. هذه التصميم يعزز أداء العزل وموثوقية الجهاز، مما يجعله مناسبًا لبيئات خارجية قاسية مختلفة.

تخطيط غرفة إخماد القوس الكهربائي:

  • تخطيط غرفة إخماد القوس الكهربائي: عادة ما يتم تثبيت غرفة إخماد القوس الكهربائي داخل الخزان. يتم تصميم هيكلها ليكون مدمجًا، مما يسمح بإخماد القوس الكهربائي بكفاءة في مساحة محدودة. بناءً على مبادئ وإجراءات إخماد القوس المختلفة، قد تختلف البنية الخاصة لغرفة إخماد القوس الكهربائي، ولكن بشكل عام تتضمن المكونات الرئيسية مثل نقاط الاتصال، والنواظير، والمواد العازلة. تعمل هذه المكونات معًا لضمان إخماد القوس الكهربائي بسرعة وكفاءة عند انقطاع التيار بواسطة القاطع.

آلية التشغيل:

  • آلية التشغيل: تشمل الآليات الشائعة آليات التشغيل باليناصيب وأجهزة التشغيل الهيدروليكية.

  • آلية التشغيل باليناصيب: هذه الآلية بسيطة في تركيبها، وذات موثوقية عالية، وسهلة الصيانة. تقوم بتشغيل عمليات الفتح والإغلاق للقاطع عن طريق تخزين وإطلاق طاقة اليناصيب.

  • آليات التشغيل الهيدروليكية: توفر هذه الآلية مزايا مثل قوة الإخراج العالية والعمل السلس، مما يجعلها مناسبة للقواطع ذات الفئة العالية من الجهد والتيار.

يجب السيطرة على معدل تسرب غاز الSF₆ بحيث يكون في مستوى منخفض للغاية، عادةً لا يتجاوز 1% سنوياً. يعتبر غاز الSF₆ غازاً دفيئاً قوياً، حيث يبلغ تأثيره الدفيئي 23,900 مرة أكثر من ثاني أكسيد الكربون. في حالة حدوث تسرب، يمكن أن يؤدي ذلك ليس فقط إلى تلوث البيئة ولكن أيضاً إلى انخفاض في ضغط الغاز داخل غرفة إخماد القوس الكهربائي، مما يؤثر على أداء وموثوقية القاطع.

لرصد تسرب غاز الSF₆، يتم عادة تركيب أجهزة كشف التسربات على قواطع الدائرة ذات الخزان. هذه الأجهزة تساعد على تحديد أي تسربات بسرعة حتى يمكن اتخاذ الإجراءات المناسبة لحل المشكلة.

خلال عمليات التشغيل العادية وقطع الدائرة للقاطع الكهربائي، يمكن أن يتحلل غاز الSF₆ وينتج عنه منتجات تحلل مختلفة مثل SF₄، S₂F₂، SOF₂، HF، وSO₂. غالباً ما تكون هذه المنتجات التحللية مسببة للتآكل أو سامة أو مهيجة، ولذلك يتطلب الأمر مراقبتها.إذا تجاوزت تركيز هذه المنتجات التحللية حدوداً معينة، فقد يشير ذلك إلى تفريغات غير طبيعية أو أعطال أخرى داخل غرفة إخماد القوس الكهربائي. من الضروري القيام بالصيانة والتعامل المناسب في الوقت المناسب لمنع المزيد من الأضرار للمعدات ولحماية صحة الموظفين.

تعرف على مورّدك

متجر إلكتروني
نسبة التسليم في الوقت المحدد
وقت الاستجابة
100.0%
≤4h
نظرة عامة على الشركة
مكان العمل: 108000m² إجمالي الموظفين: 700+ أعلى قيمة تصدير سنوية (دولار): 150000000
خدمات
نوع العمل: تصميم/تصنيع/المبيعات
الفئات الرئيسية: محول كهربائي/محطات التحويل المجمعة والغرف الكهربائية سابقة التجهيز/العزل الواقي من البرق والحماية من الصواعق/أجهزة كهربائية ذات فولطية عالية/لوحات كهربائية وأجهزة تحكم/محول كهربائي
إرسال الاستفسار
+86
انقر لتحميل الملف
تنزيل
الحصول على تطبيق IEE Business
استخدم تطبيق IEE-Business للعثور على المعدات والحصول على حلول والتواصل مع الخبراء والمشاركة في التعاون الصناعي في أي وقت ومن أي مكان - دعمًا كاملاً لتطوير مشاريعك الكهربائية والأعمال
تسجيل الدخول
أو المتابعة باستخدام
هل أنت جديد هنا؟
تسجيل