Search


RVD-145  Dead tank vacuum circuit breaker
Brochure · ROCKWILL

RVD-145 Dead tank vacuum circuit breaker

145 kV SF6‑free dead‑tank vacuum circuit‑breaker, rated current 3150A, short‑circuit breaking current 50kA, clean‑air insulation, spring‑stored‑energy drive, indoor‑outdoor dual‑use for high‑voltage transmission substation.

Add us on Google
Updated2026.09
LanguageEnglish
FilePDF · 584.5 KB
Dead tank VCBVCB
Download

Document description

This PDF product catalogue supports tender comparison, high‑voltage transmission‑substation project selection and pre‑sales technical evaluation. This dead‑tank vacuum circuit‑breaker complies with IEC 62271‑1, IEC 62271‑100 and relevant ANSI/IEEE standards.

It adopts vacuum interrupter with zero‑F‑gas clean‑air insulating medium of zero GWP, achieving type‑tested gas‑compartment annual leakage rate below 0.1 %, rated absolute filling pressure 0.8 MPa. This catalogue records full dielectric‑withstand values, peak & 3‑second short‑time withstand‑current grades, multiple reclosing operating‑sequences, wide ambient‑temperature range of ‑50 ℃ ~ +55 ℃, >25‑year first major‑inspection interval and >50‑year expected service‑life.

Modular structure with compact bay dimension, optional integrated LPIT low‑power instrument transformer, spring‑stored‑energy actuator, supports both indoor and outdoor deployment. Custom‑manufacturing covering design adjustment, assembly and project‑specific factory‑acceptance‑test is available for high‑voltage grid projects. Please contact us for complete dimension drawings and full set of type‑test reports.

Related Products

Frequently asked questions

Optimized tank‑sealing and modular design satisfy environmental requirements for both indoor‑substation halls and outdoor transmission‑site applications. Please contact us for installation‑layout suggestion.

Clean‑air insulation will not liquefy under extremely low temperature down to ‑50 ℃, removing extra anti‑liquefaction heating‑system investment for cold‑region substations. Please contact us for low‑temperature‑adaptation advice.

It uses zero‑GWP clean‑air without any fluorinated greenhouse‑gas, eliminates SF6‑related gas‑handling, reporting and end‑of‑life disposal work, complying with global F‑gas‑restriction trends. Please contact us for eco‑solution introduction.

WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register