Eco‑friendly Dead Tank Vacuum Circuit Breaker(VCB)-36kV 72.5kV

Add us on Google
  • Eco‑friendly Dead Tank Vacuum Circuit Breaker(VCB)-36kV 72.5kV

Key attributes

Brand ROCKWILL
Series RVD
Rated voltage 36/72.5kV
Rated frequency 50/60Hz
Rated normal current 2000/3150A
Rated short circuit breaker current 31.5/40kA
Closing operation system Spring
Description

As a trusted SF6 Free Dead Tank Vacuum Circuit Breaker China Manufacturer, ROCKWILL provides OEM/ODM services. Developed based on advanced core technologies and mature mass-production experience, the dry-air insulated dead-tank vacuum circuit breaker adopts vacuum interrupters for arc extinction and dry air as insulating medium. No decomposition of insulating gas occurs during current interruption, delivering high reliability and outstanding operational performance.

Rockwill Product Showcase Video

Product Features

  • Optimized for green procurement, this dead-tank VCB is designed under two core concepts: first, complying with eco-friendly design standards including the 3R principle (Reduce, Reuse, Recycle) and LS criteria (Long service life & Separable structure); second, cutting down the Life Cycle Cost (LCC) to balance economic efficiency and environmental protection.
  • Superior Interruption Performance:Equipped with vacuum interrupters for each breaking pole, the product features outstanding dielectric recovery capacity and achieves reliable performance under severe working conditions such as short-circuit interruption and short-line fault interruption.
  • Strong Resistance to Multiple Surges and Evolving Faults:Fitted with full self-arc-diffusion vacuum interrupters, the breaker can withstand multiple lightning surges and reliably interrupt evolving fault currents to accommodate complicated grid fault conditions.
  • Reduced Maintenance Workload:The vacuum-based breaking unit requires no routine inspection on core arc-extinguishing components, significantly saving maintenance man-hours and lowering long-term service costs.

Specifications

Rated voltage (kV)

36

72.5

Rated frequency (Hz)

50/60

Rated normal current (A)   

2000

2000/3150

Lightning Impulse Withstand Voltage

General Value (Phase-to-Earth / Phase-to-Phase

170 kV

325 kV

Across Isolating Distance

195 kV

375 kV

Power-Frequency Withstand Voltage 

General Value (Phase-to-Earth / Phase-to-Phase)

70 kV

140 kV

Across Isolating Distance

95 kV

160 kV

Rated short circuit breaker current (kA)

31.5

40

Rated transient recovery voltage 

Rate of rise (kV/μs)

1.19

1.47

First pole to clear factor

1.5

Rated short circuit making current (kA)

82

104

Rated short time current (kA)

31.5 (3s)

40 (3s)

Rated breaking time (cycle)

3

Rated opening time (s)

0.033

0.03

Make time with no load (s)

0.05

0.10

Operating duty

O-0.3s-CO-15s-CO

Closing control voltage (Vdc)

48, 100, 110, 125, 250

Rated tripping voltage (Vdc)

48, 100, 110, 125, 250

Supply voltage for

charging motor

(Vdc)

48, 100, 110, 125, 250

(Vac)

60, 120, 240

Rated dry-air pressure

0.5MPa-g (at 20℃ )

Closing operation system

Spring

Tripping control system

Spring

Applicable standard

IEC 62271-100-2021, IEEE C37.04-2018

Construction

Overall construction

For each phase, a current breaking vacuum interrupter is accommodated in the grounded tank. The operation system is such that closing and tripping are effected by spring force.The operating mechanism and 3-phase interlinkage are assembled on a common base, which is installed on the frame legs.

Internal construction

The overall structure is composed mainly of grounded tank, vacuum interrupters (VI), insulating rods, bushings and main circuit terminals. Each grounded tank is filled with dry air maintained at a rated pressure of 0.5MPa-g (20℃).

Internal construction of vacuum circuit breaker

vacuum circuit breaker Internal construction

Performance

Performance of the circuit breaker has been designed in accordance with ANSI and IEC standard, and verified by type test. All products are shipped after confirmation of various performances by acceptance test based on these standards.

  • Withstand voltage characteristics :Performance of withstand voltage is assured at the specified dry air pressure. Even though the dry air pressure has been lowered to the alarming level, the required insulation level can be assured.In addition, even though this pressure lowers to the atmosphericpressure, the circuit breaker withstands the rated voltage.

  • Current passing performance :Since the main contacts are located under vacuum, their surfaces are never oxidized and current passing performance is therefore stabilized. In the closing mode of circuit breaker, a pressing force is exerted between main contacts by the effect of pressing spring and sufficient tolerance is assured against closing current and short-time current.

Environmental Conditions

Ambient air temperature upper limit +40 °C
Ambient air temperature 24-hour average +35 °C
Ambient air temperature lower limit –25 °C
Altitude above sea level ≤ 1000 m
Relative humidity (24-hour average) ≤ 95%
Relative humidity (monthly average) ≤ 90%
Water vapor pressure (24-hour average) ≤ 2.2 kPa
Water vapor pressure (monthly average) ≤ 1.8 kPa
Solar radiation ≤ 1000 W/m²
Pollution level Level III

Application Scenarios

  • Green / Eco-Procurement Substations
  • Urban & Industrial Distribution (36kV / 72.5kV)
  • SF₆-Free / Zero-Gas-Decomposition Sites
  • High Lightning / Evolving-Fault Grid Areas
  • Low-Maintenance & Life-Cycle-Cost-Sensitive Projects
  • Renewable Step-Up & Industrial Dedicated Supply

Solutions - Dead Tank Circuit Breaker

  • Rockwill’s Arc Quenching Technology for MV/HV Circuit Breakers: From Classical Interruption to Intelligent Coordination
    Rockwill's arc quenching technology system is essentially a microcosm of the power switchgear field's response to the dual challenges of "higher interrupting performance" and "zero environmental impact across the entire lifecycle." Its complete landscape consists of three parts: high-performance hardware arc quenching platforms, stringent standard certification systems, and future-oriented intelligent switching control strategies. This constitutes a capability leap from "being able to interrupt"
  • South Africa Regional Dead Tank SF6 Circuit Breaker Solution Report
    Ⅰ. Project BackgroundAs the first African country adopting dead tank SF₆ circuit breaker technology, South Africa's grid system faces these challenges: Aging Dead Tank SF₆ Circuit Breakers:Existing high-voltage circuit breakers exhibit severe aging, particularly legacy dead tank SF₆ circuit breakers with increased failure rates. Dead Tank SF₆ Circuit Breaker Limitations:In high-altitude regions (>2,000m), conventional dead tank SF₆ circuit breakers experience insulation degradation from low-t
  • Dead Tank SF6 Circuit Breaker Solution for African Plateau Regions (Ethiopia)
    Project BackgroundEthiopia, located in the East African plateau, has an average altitude exceeding 3,000 meters. In some areas, winter temperatures can drop to -30°C, accompanied by significant diurnal temperature variations (up to 25°C daily) and intense ultraviolet radiation. The local power system faces the following challenges: SF₆ Gas Liquefaction Risk:Traditional Dead Tank SF₆ Circuit Breakers are prone to SF₆ gas liquefaction at low temperatures (critical liquefaction temperature ≈ -28.5°

Documentation Resource Library Dead Tank Circuit Breaker

Dead Tank Circuit Breakers Catalog
Restricted
Dead Tank Circuit Breakers Catalog Dead Tank Circuit Breakers Catalog
Catalogue
English
PDF
RVD-145 Dead tank vacuum circuit breaker
Restricted
RVD-145 Dead tank vacuum circuit breaker RVD-145 Dead tank vacuum circuit breaker
Catalogue
English
PDF
RVD-145  Dead tank vacuum circuit breaker
Public
RVD-145 Dead tank vacuum circuit breaker RVD-145 Dead tank vacuum circuit breaker
Brochure
English
RVD Dead tank SF6 Free/vacuum circuit breaker
Public
RVD Dead tank SF6 Free/vacuum circuit breaker RVD Dead tank SF6 Free/vacuum circuit breaker
Brochure
English
Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

The interrupter is typically installed inside the tank, resulting in a highly compact overall structure that enables efficient arc quenching within a limited space. Depending on the arc extinguishing principle and technical approach, the specific configuration of the interrupter may vary, but all designs include core components such as moving/stationary contacts, a nozzle, and insulating parts. During opening operation to interrupt the current, these components work together to achieve fast and reliable extinction of the arc.

The core difference is the arc-extinguishing medium. A VCB uses a high vacuum inside a sealed ceramic or glass envelope — the vacuum rapidly diffuses ions and metal vapor after current zero, achieving arc extinction in <10 ms. An SF₆ CB uses sulfur hexafluoride gas, which has strong electron affinity — it captures free electrons to form heavy negative ions, quickly depleting the arc channel's conductivity.

Rockwill’s SF6-free eco-friendly vacuum circuit breakers (rated up to 40.5kV) are built on a proprietary, fully independent R&D technical system, offering significant scalable and series-based advantages. Furthermore, backed by our rigorous digital manufacturing management system, we formally commit to and strictly fulfill a 10-year warranty requirement.

Rockwill is an open-minded, professional R&D and manufacturing enterprise. We fully accept ODM/OEM partnership orders from Europe, North America, and all other global regions.

Rockwill’s 60kV, 63kV, 66kV, and 72.5kV products belong to a series-based product line developed on a single technical platform. In contrast, the 88kV to 123kV and 145kV ranges belong to a separate technical platform series. Rockwill is currently dedicated to developing the next generation of smarter, longer-lifespan HV eco-friendly SF6-free switchgear; please feel free to contact us for further details.

Yes. Rockwill is continuously driving technological advancements in greener, more reliable, and smarter high-voltage switches. We will gradually extend our product portfolio to even higher voltage levels in the future.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register