RVD Dead tank SF6 Free/vacuum circuit breaker
Brochure · ROCKWILL

RVD Dead tank SF6 Free/vacuum circuit breaker

12‑145 kV SF6‑free dead‑tank vacuum circuit‑breaker, rated current 1250‑3150A, short‑circuit breaking current 25‑50kA, clean‑air insulation, spring‑stored‑energy drive, indoor‑outdoor dual‑use, ultra‑low gas‑leakage rate for transmission & distribution gr

Add us on Google
Updated2026.09
LanguageEnglish
FilePDF · 408.8 KB
vacuum circuit breakerDead tank vacuum circuit breaker
Download

Document description

This PDF product flyer serves for tender comparison, transmission‑distribution‑project selection and pre‑sales technical evaluation. The equipment complies with IEC 62271‑100 for AC high‑voltage circuit‑breakers and IEEE C37.04‑2018, adopting vacuum interrupter with zero‑fluorinated‑greenhouse‑gas content and clean‑air insulating medium.

This datasheet records full dielectric‑withstand values, peak & short‑time withstand‑current grades, type‑tested annual compartment gas‑leakage rate below 0.1 %, rated filling absolute pressure, bay width dimension, wide ambient‑temperature range of ‑50 ℃ ~ +55 ℃, multi‑mode reclosing operating‑sequence, >25‑year first major‑inspection interval and >50‑year expected service‑life.

Equipped with modular spring‑stored‑energy actuator and complete standardized accessories & spare‑parts, it supports both indoor and outdoor deployment. Custom‑manufacturing covering design adjustment, assembly and project‑specific factory‑acceptance‑test is available for various power‑grid projects. Please contact us for complete dimension drawings and full set of type‑test reports.

Related Products

Frequently asked questions

Optimized tank‑structure and gas‑sealing design together with matching standard‑accessories satisfy environmental requirements for both indoor‑substation and outdoor‑transmission‑site conditions. Please contact us for installation‑layout suggestion.

Extended first‑overhaul cycle lowers site‑maintenance frequency, cuts outage‑related costs and improves grid equipment availability. Please contact us for maintenance‑cycle guidance.

It uses vacuum interrupter together with clean‑air insulation, contains zero fluorinated greenhouse‑gas, eliminates SF6‑related emission, recovery and disposal‑work. Please contact us for eco‑solution introduction.