  • Sensitive Industries Voltage Sag Mitigation System

Key attributes

Brand Rw Energy
Model NO. Sensitive Industries Voltage Sag Mitigation System
Rated voltage 400V
Rated capacity Up to 34.5kV
Series RWDVR

Product descriptions from the supplier

Description

Product overview

The Voltage Sag Mitigation Solution for Sensitive Industries is a specialized device designed to protect sensitive loads from power quality disturbances, particularly voltage sags.

In simple terms, when sensitive equipment is connected to the AC power grid, disturbances such as voltage dips, sudden fluctuations, or harmonic distortions can significantly affect performance, stability, and even cause operational interruptions.

To minimize these impacts, a Dynamic Voltage Restorer (DVR) is connected in series with the three-phase circuit. During grid faults or disturbances, the DVR injects compensating voltage into the load side, ensuring stable and reliable voltage supply to sensitive equipment.

This solution is particularly critical in industries where high reliability and stability are essential, such as:

  • Semiconductor and electronics manufacturing
  • Pharmaceutical and biotechnology plants
  • Precision equipment and data centers
  • Petrochemical and chemical processing facilities

By mitigating voltage sags and harmonics, the system ensures consistent power quality, protecting sensitive industrial processes and reducing production downtime.

Main Features

  • High reliability: Purpose-designed for industrial loads
  • Fast response: High efficiency and quick compensation
  • Excellent waveform quality: No harmonic injection
  • DSP-based digital control: Stable and reliable operation
  • Expandable design: Advanced capacity expansion and modular structure
  • User-friendly display: TFT color multifunction panel
  • Low operation cost: Maintenance-free, long service life
  • Compact design: Small footprint, optimized for installation in constrained spaces

Model Description

RWDVR 04–300 H F N–040 C

  • C / A: Supercapacitor / Electrolytic capacitor
  • Protection time (s): e.g., 040 = 0.4 s
  • N: Three-phase four-wire (no N = three-phase three-wire)
  • F / B: Front access / Rear access
  • H / L: Top access / Bottom access
  • Rated protection capacity (kVA): e.g., 300 = 300 kVA
  • Voltage class (kV):
    • 02 = 208 V
    • 04 = 400 V
    • 06 = 600 V
    • 6 = 6 kV
    • 10 = 10 kV
  • DVR: Dynamic Voltage Restorer
  • Brand: Rockwill Energy

 Notes:

  1. Protection time is a three-digit scientific notation, unit in seconds (s). For example, 363 = 3.6 × 10³ s (≈1 hour), 040 = 0.4 s.
  2. Rated protection capacity range: 30–5000 kVA (see technical parameters table).

Technical Parameters

208V Series DVR

Model

DVR02-30

DVR02-50

DVR02-75

DVR02-100

DVR02-150

DVR02-300

DVR02-500

DVR02-750

DVR02-1000

Rated Capacity (kVA)

30

50

75

100

150

300

500

750

1000

Rated Voltage (Un)

208V ± 15%

Rated Current (A)

83

139

208

278

416

833

1388

2082

2776

Dimensions (W×D×H mm)

700×800×2000

800×800×2100

1000×800×2100

1300×800×2200

1800×800×2200

2400×1000×2200

3000×1200×2200

   

Storage Size (mm)

600×800×2200

600×1000×2200

   

Minimum Output Voltage (Umin)

0%

Protection Time (s)

0.4–30 s adjustable

Fault Ride-through

Available

Ambient Temperature

–25°C ~ +45°C (above 40°C, derating by 2%/°C)

Relative Humidity

≤95%, non-condensing

Altitude

0–3000 m (above 2000 m, derating 1% per 100 m)

Protection Level

IP21 or IP23

Pollution Degree

Class 2

Noise Level

<40 dB

Display

8-inch TFT color LCD

Communication

Modbus/TCP, RS485, GPRS

 

400V Series DVR

Model

DVR04-30

DVR04-50

DVR04-75

DVR04-100

DVR04-150

DVR04-300

DVR04-500

DVR04-750

DVR04-1000

DVR04-1250

DVR04-1500

DVR04-2000

Rated Capacity (kVA)

30

50

75

100

150

300

500

750

1000

1250

1500

2000

Rated Voltage (Un)

400V ± 5%

Rated Current (A)

43

72

108

144

288

432

720

1080

1440

1800

2160

2800

Dimensions (W×D×H mm)

700×800×2000

800×800×2100

1000×800×2100

1300×800×2200

1600×800×2200

1900×800×2200

2400×1000×2200

3300×1000×2200

       

Storage Size (mm)

400×800×2100

600×800×2200

600×1000×2200

             

Other parameters

Same as 208V Series

 

600V Series DVR

Model

DVR06-300

DVR06-500

DVR06-750

DVR06-1000

DVR06-1250

DVR06-1500

DVR06-2000

DVR06-3000

Rated Capacity (kVA)

300

500

750

1000

1250

1500

2000

3000

Rated Voltage (Un)

600V ± 15%

Rated Current (A)

288

480

720

960

1200

1440

1920

2880

Dimensions (W×D×H mm)

1300×800×2200

1900×800×2200

2100×800×2200

2400×800×2200

2700×800×2200

4000×1000×2200

4800×1000×2200

 

Storage Size (mm)

600×800×2200

600×1000×2200

           

Other parameters

Same as 208V Series

 

6kV Series DVR

Model

DVR6-300

DVR6-500

DVR6-750

DVR6-1000

DVR6-1250

DVR6-1500

DVR6-2000

DVR6-3000

DVR6-5000

Rated Capacity (kVA)

300

500

750

1000

1250

1500

2000

3000

5000

Rated Voltage (Un)

6kV ± 15%

Rated Current (A)

29

48

72

96

120

144

192

288

480

Dimensions (W×D×H mm)

600×800×2100

700×800×2100

900×800×2200

1200×1000×2200

1500×1000×2200

1800×1000×2200

2500×1200×2200

3900×1200×2200

 

Storage Size (mm)

1200×1000×2100

1400×1300×2200

1700×1400×2200

2500×1600×2200

         

Other parameters

Same as 208V Series

 

10kV Series DVR

Model

DVR10-300

DVR10-500

DVR10-750

DVR10-1000

DVR10-1250

DVR10-1500

DVR10-2000

DVR10-3000

DVR10-5000

Rated Capacity (kVA)

300

500

750

1000

1250

1500

2000

3000

5000

Rated Voltage (Un)

10kV ± 15%

Rated Current (A)

17

29

43

57

71

86

114

171

285

Dimensions (W×D×H mm)

600×800×2100

900×800×2200

1200×1000×2200

1500×1000×2200

2000×1000×2200

2500×1600×2200

3900×1600×2200

   

Storage Size (mm)

1200×1000×2100

1400×1300×2200

1700×1400×2200

2500×1600×2200

         

Other parameters

Same as 208V Series

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.