• Pro B Busway system
Pro B Busway system
discuss personally
Model
Pro B Al-core
Basic info
Brand Wone Store
Model NO. Pro B Busway system
Rated voltage 1kV
Rated normal current 5000A
Rated frequency 50/60Hz
alloy code TMY
Series Pro B Series
Product Detail

Overview

Pro B busway adopts a new design, from the inside to the outside, exudes a unique charm, and enjoys the convenience and safety brought by technological innovation.

l  Unique technological charm

High conductivity conductor, save 21% power than normal aluminum conductor;

High heat dissipation housing, lower temperature rise, longer product life;

Composite insulation design, stronger ability to withstand impulse voltage;

The integrated side plate makes the grounding continuity more reliable;

The patented design of P Elastic Joint® Elastic Joint™ reduces the area of the existing plug-in interface by more than 50%. The parallel connection technology of dual-plug interfaces can truly realize fully compatible plug-in connections below 1000A. The pin adopts a patented elastic design, which can automatically compensate for the deformation during long-term operation.

The plug-in box can provide 16A ~ 1600A tapping current with 7 different sizes.

- Designed with support positioning device to ensure accurate positioning and support the weight of the plug-in box to protect the pins from external forces.

- Designed with the double interlocking mechanism, and the power-on state cannot be inserted and removed, thus ensuring the personal safety of the operator.

- Any type of circuit breaker can be equipped in the box, the breakers type and brand are optional for customer.

 

technology parameters

Conductor Type

Al

Rated Current

250-5000A

Frequency

50Hz/60Hz

Rated Voltage

1000V

IP

IP54/IP65/IP66 

Product Series

Pro B Series Compact Busway

Design standard

IEC61439-1;IEC61439-6;GB/T7251.1;GB/T7251.6;IEC60331;IEC 60529

Product Type

Low Voltage Busway

System

3P3W/3P4W/3P5W

 

Application

Commercial buildings, high-rise, industrial plants, data centers, rail transit, etc. 

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!