• Photovoltaic power generation inverter isolation transformer
Photovoltaic power generation inverter isolation transformer
discuss personally
Model
SGG-250kVA
SGG-320kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic power generation inverter isolation transformer
Rated frequency 50/60Hz
Rated capacity 250kVA
Series SGG
Product Detail

Product Overview:

Photovoltaic power generation inverter isolation transformer is a technology that directly converts light energy into electrical energy by using the photogenerated volt effect at the semiconductor interface. The key element of this technology is the solar cell. Solar cells can be encapsulated and protected in series to form large-area solar cell modules. Combined with the power controller and other components, a photovoltaic power generation device is formed.

Photovoltaic transformers are generally used for solar inverters. Because the photovoltaic transformer itself has low photoelectric efficiency. Therefore, the high efficiency of the transformer is especially required.

Grid-side wiring of photovoltaic grid-connected inverter isolation transformer. Dyn11. YD5. Phase shift 120 degrees. The PV isolation transformer can be set to work during the day. Stop at night to reduce no-load loss of electrical energy.Three-phase photovoltaic transformer parameters for reference.

Key Features:

  • Dedicated to PV systems, it achieves electrical safety isolation, blocks grid interference, provides a pure power environment for inverters, and ensures stable operation.
  • Supports flexible voltage matching, adapts to the voltage requirements of various photovoltaic inverters, realizes precise voltage transformation, transmits electrical energy efficiently, and improves power generation utilization.
  • Adopts high - quality iron core and winding technology, featuring low loss, high efficiency, and low temperature rise, which extends the equipment service life and reduces the operation and maintenance costs of the photovoltaic system.
  • Possesses strong anti - interference capability, suppresses harmonics, surges, etc., ensures the output power quality of the inverter, and is suitable for complex photovoltaic application scenarios.
  • Compact structure, suitable for the spatial layout of photovoltaic power stations; excellent protection performance, adaptable to outdoor temperature differences, humidity and other environments, and operates stably and reliably.

Technical data:

Conditions of Use. Working environment temperature: 15~+50℃

Operating ambient temperature:20—90%RH

Atmospheric pressure in the working environment:860 hpa---1060 hpa

Storage/transport temperature. 20℃-- +55℃

Main technical features:AA

Rated capacity:5KVA—1000KVA

Input Voltage: Rated voltage 270V or 315V

Input current by actual voltage

Output voltage: Rated voltage: 380V or 400V

The output current is based on the actual voltage

Connection mode :dyn11

Efficiency: ≤98.5%

Frequency: 50HZ/60HZ

Insulation resistance :25A less than 500MΩ

Induction withstand voltage: 125HZ/800y/60

Insulation Chip Class: H (Temperature Resistance 180 °C)

Noise :≤30dB)

Temperature rise :≤ allows for a temperature rise of 115k

Impedance Voltage Drop: ≤4%

Structure: Forced air cooling, waiting for the temperature controller, according to customer requirements, reach a certain temperature, the fan will be automatically opened.

Degree of protection :IP00

Anti-interference mode: copper foil isolation shielding grounding:

Waveform Distortion :No additional waveform distortion.

Electrical strength: Power frequency sinusoidal voltage 3000V, which lasts for one minute, without breakdown and flashover

Insulation resistance (input and output to ground) Test voltage at least 1000V DC insulation resistance greater than 1000 Overload capacity Twice the rated current for one minute..

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!