• Outdoor 27kV/630A SF6 load break switch
Outdoor 27kV/630A SF6 load break switch
discuss personally
Model
RPS-27KV-630A
RPS-27kV/630A
RPS-27kV/630A
RPS-27kV/630A
Basic info
Brand ROCKWILL
Model NO. Outdoor RPS-27kV/630A SF6 load break switch
Rated voltage 27kV
Rated normal current 630A
Power frequency withstand voltage
Mainly active load breaking current
Series SF6
Product Detail

Description:

  • This is a high standard design SF6 gas load break switch which is suit for pole mounted.

  • RPS type load break switch is KEMA type tested.

  • RPS type load break switch can combined as below different functions switchgear.

  • Manual type load break switch.

  • Motorize type load break switch.

  • Remote control load break switch.

  • Automatic sectionalizer.

Features:

  • the high quality 3 mm stainless steel are used for tank.

  • minimum welding line to minimize corrosion, and specifically to guarantee the safety of the  operation personnel.

  • even with the internal arc faults at the maximum fault capacity of the tank the RPS can  withstands an internal fault without venting hot gases.

  • the independent spring operation mechanism adopt ROCKWILL® patent spiral spring, provides a guaranteed load  break fault make capability by ensuring. the opening and closing speed of the switch.

  • provided with light reflecting position indicator which are directly connected to the switch operating  shaft providing clear and unambiguous switch position. indication

  • indicator made of light reflecting material, which  is easily visible from ground level even at night in driving rain.

Parameters:

image.png

image.png

Monitoring Functions:

image.png

External dimensions:

image.png

Size

889mmx1268mmx557mm


Environmental requirement:

image.png


Product show:

image.png

How to maintain and manage the outdoor load disconnect switch?

Regular Maintenance:

  • Visual Inspection: Conduct regular visual inspections to ensure that the switchgear's housing, connection points, and seals are free from obvious damage or corrosion.

  • Internal Inspection: Perform regular internal inspections, particularly of critical components such as the arc quenching chamber, contacts, and insulating parts, to ensure they are in good condition.

  • Functional Testing: Carry out regular functional tests, including opening and closing operations, insulation resistance testing, and dielectric strength testing, to ensure all functions of the switchgear are operating correctly.

Gas Pressure Monitoring:

  • Pressure Monitoring: For outdoor load break switches using SF6 gas, regularly monitor the SF6 gas pressure in the arc quenching chamber to ensure it remains within the specified range.

  • Leakage Detection: Use leakage detection equipment to regularly check for SF6 gas leaks, and address any detected leaks promptly.

Environmental Control:

  • Temperature Control: Control the installation environment's temperature to avoid high or low temperatures that could affect the performance of the switchgear.

  • Moisture Protection: Implement moisture protection measures to prevent water from entering the switchgear, which could impact its insulation performance and the normal operation of mechanical components.

 


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!